English
Language : 

PH100F24 Datasheet, PDF (1/3 Pages) List of Unclassifed Manufacturers – PH100F24
PH100F24
NEMIC-LAMBDA
SPECIFICATION
C101-01-01A
MODEL
PH100F PH100F PH100F PH100F PH100F PH100F PH100F
ITEMS
24-2 24-3
24-5
24-12 24-15 24-24 24-48
1 Nominal Output Voltage
V
2
3
5
12
15
24
28
2 Maximum Output Current
A 20
20
20
8.4
6.7
4.2
3.6
3 Nominal Output Power
W 40
60
100
100.8 100.5 100.8 100.8
4 Efficiency (Typ.)
(*1) % 66
70
80
81
82
83
83
5 Input Voltage Range
-
18 ~ 36VDC
6 Input Current (Typ.)
(*1) A 2.53 3.57
5.21
5.19 5.11 5.06 5.06
7 Output Voltage Accuracy
8 Output Voltage Range
(*1) -
(*10) -
±20%
±1%
+20%, -60%
9 Maximum Ripple & Noise (*9) mV 100
100
100
150
150
240
280
10 Maximum Line Regulation (*2) mV 20
20
20
48
60
96
112
11 Maximum Load Regulation (*3) mV 40
40
40
96
120
192
224
12 Over Current Protection
(*4) A
105% ~ 140%
13 Over Voltage Protection
(*5) V 165% ~ 240%
125% ~ 145%
14 Remote Sensing
(*8) -
Possible
15 Remote ON/OFF Control
(*8) -
Possible (SHORT:ON OPEN:OFF)
16 Parallel Operation
(*8) -
Possible
17 Series Operation
(*8) -
Possible
18 I.O.G. Signal
(*8) -
Possible (Open Collector Output)
19 Operating Temperature
(*6) -
- 20°C ~ + 85°C (Base plate) Ambient Temperature MIN = - 20°C.
20 Operating Humidity
-
30 - 95%RH (No Dewdrop)
21 Storage Temperature
-
- 40°C ~ + 85°C
22 Storage Humidity
-
10 - 95%RH (No Dewdrop)
23 Cooling
(*7) -
Conduction Cooled
24 Temperature Coefficient (%)
-
0.02% / °C
25 Withstand Voltage
-
Input-Baseplate : 2kVAC, Input-Output : 2kVAC(20mA) for 1min
-
Output-Baseplate : 500VDC(100mA) for 1min
26 Isolation Resistance
- More than 100Mohm at 25°C and 70%RH Output-Baseplate...500VDC
27 Vibration
28 Shock
-
At No Operating, 10-55Hz (Sweep for 1min)
-
Amplitude 0.825mm Constant (Maximum 49.0m/s2) X,Y,Z 1h each
-
196.1m/s2 (In package)
29 Weight (Typ.)
-
180g
30 Size (W x H x D)
mm
83 x 12.7 x 86 (Refer to Outline Drawing)
=NOTES=
*1. At 24VDC and Maximum Output Current.
*2. 18 ~ 36VDC, Constant Load.
*3. No load ~ Full load, Constant input voltage.
*4. Constant current limiting with automatic recovery.
*5. Inverter shutdown method, Manual Reset.
*6. Ratings - Refer to Derating Curve on the Right.
- Load(%) is Percent of Maximum Output
Current.
*7. Heatsink has to be Chosen According to Instruction
Manual.
*8. Refer to Instruction Manual.
*9 External Components are Needed for Operation.
(Refer to Basical Connection and Instruction Manual)
*10 At 24VDC Input.(Refer to Instruction Manual.)
*DERATING CURVE*
100
80
60
40
20
0
-20 0 20 40 60 8805 100
Baseplate (°C)