English
Language : 

P110-6000 Datasheet, PDF (1/8 Pages) List of Unclassifed Manufacturers – INTELLIMISTTM Residential Atomizing Humidifier and Control
INSTALLATION
INSTRUCTIONS
INTELLIMIST™
Residential Atomizing
Humidifier and Control
Part Numbers: P110-6000 (INTELLIMIST Humidifier and Humidistat)
P110-6001 (INTELLIMIST Humidifier and INTELLISTAT™ Control)
CONTENTS
Page
SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
INSTALLATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Humidifier and Filter Installation . . . . . . . . . . . . . . . . . . . . . . . .2
Water Supply Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Drainage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Humidistat or INTELLISTAT Control
Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
SAFETY CONSIDERATIONS
Installation and servicing of air-conditioning equipment can
be hazardous due to system pressure and electrical compo-
nents. Only trained and qualified service personnel should in-
stall, repair, or service air-conditioning equipment.
Untrained personnel can perform basic maintenance func-
tions such as changing filters. All other operations should be
performed by trained service personnel. When working on air-
conditioning equipment, observe precautions in the literature,
tags and labels attached to the unit or accessory, and other safe-
ty precautions that may apply.
Follow all safety codes. Wear safety glasses and work
gloves.
NOTE: Refer to Humidistat or INTELLISTAT control Installa-
tion and Operating Instructions for more information on those
devices.
PACKAGE CONTENTS
QUANTITY
1
1
1
1
1
1
1
ITEM
Humidifier
Humidistat (P110-6000) or
INTELLISTAT Control (P110-6001)
Spray Nozzle
1/4-in. OD Plastic Tubing (20 ft)
In-Line Water Filter
Water Filter Mounting Bracket
Mounting Kit Containing:
1 — Humidifier Mounting Template
8 — No. 6 Mounting Screws
2 — Threaded Adapters
3 — Locking Nuts
1 — Self Piercing Valve Installation Kit*
1 — Teflon Tape
2 — Plastic Water Filter Mounting Bands
*Contains the following: self-piercing valve, rubber gasket, 2 bolts
and nuts, flange, brass nut, brass ferrule, brass insert.
INSTALLATION
Location — The INTELLIMIST humidifier should be lo-
cated on the supply air plenum. Use only with central air-
conditioning systems. See Fig. 2.
Before installing an accessory or performing maintenance
or service on humidifier, turn off main power switch to
unit. Electrical shock can cause injury or death. There may
be more than one disconnect switch.
GENERAL
The INTELLIMIST humidifier is an atomizing humidifier.
The INTELLIMIST humidifier is normally located in the
supply plenum and adds up to 24 gallons of humidity per day
to the supply air using MICROPULSE™ technology to assure
maximum efficiency. The INTELLIMIST humidifier is
designed for use with 1 to 7.5 ton HVAC systems. Only the
following controls may be used with the INTELLIMIST hu-
midifier: the P110-0009 Humidistat, and the P374-1600
INTELLISTAT combination temperature and humidity con-
trol. Humidifier dimensions are shown in Fig. 1.
Do not use the humidifier with any non-approved humidi-
stat or control. Damage to the unit may result.
The humidifier must be mounted over the evaporator coil
or evaporator coil drain pan. Water damage may result.
Adequate air and moisture mixing is essential to ensure that
water does not accumulate in ductwork.
Make sure site can be supplied with the necessary power re-
quirements. Ensure that there is adequate clearance for service.
Humidifier must not be installed where freezing tempera-
tures may occur. Do not install on furnace jacket or where hu-
midifier or components may be exposed to hot surfaces.
On vertical equipment, allow clearance for the humidifier,
filter, and water line away from furnace exhaust vent.
Always install downstream of electric heat elements and
electronic air cleaner.
Manufacturer reserves the right to
discontinue, or change at any time,
specifications or designs without notice
and without incurring obligations.
REPLACEMENT COMPONENTS DIVISION
© CARRIER CORPORATION 5-01
PRINTED IN U.S.A.
LITERATURE NUMBER HUM-55SI
CATALOG NUMBER 570-452
REPLACES: HUM-53SI