English
Language : 

MPE-8071 Datasheet, PDF (1/1 Pages) List of Unclassifed Manufacturers – 70W AC-DC OPEN FRAME POWER SUPPLY INPUT RANGE : 85-270VAC
Power Supply
MPE-8071
70W AC-DC Open Frame Power Supply
Input Range: 85~270VAC
12.7
11.56
TO CHASSIS GROUNDING
TB2
E
0V
+15V
TRANSFORMER
4.0TYP. MOUNTING HOLES
TB2
1
TB3
Pin Output
1~3 +5V
4~6 GND
7
+12V
8
-12V
Output
+5V
+12V
-12V
Min.
Load
0A
0A
0A
Rated
Load
10A
1.5A
0.3A
Max.
Load
12A
2.5A
0.3A
Valtage
Accuracy
5~5.1V
11.2~11.6V
-10.8~-12V
Specifications
* Input Voltage: 85~270VAC
* Input Current: 2A at 115VAC or 1A at 230VAC max.
* Inrush Current: Does not exceed 30A at 115VAC input or 60A at
230VAC input, at cold start 25oC, and excluding EMI suppression
capactiors
* Load Range: All outputs are at min. load conditions, while +5V
output is between 5~5.1V and all other outputs are within the
specified voltage accuracy range
* Ripple and Noise: Peak to peak ripple and noise for all outputs is <
1% of output voltage at rated load
* Line Regulation: < +/-2% for each output measured at rated load
and +/-10% input voltage range
* Load Regulation: < +/-3% for +5V, +/-4% for +12V, and +/-5% for -
12V with +/-40% change on the measured output load, +/-40% from
60% rated load, while keeping other outputs at 60% rated load
* Hold Up Time: > 16ms at 115VAC input and rated load, measured
from the end of the last charging pulse to when the main output
drops down to 95% output voltage
* Efficiency: > 70% at nominal line and rated load
* Altitude: 10,000 feet
* Protection: Latch-off mode against short circuit or over load
conditions AC input ON/OFF cycle to restart power supply
* Temperature: 0~50oC (operating); -40~+85oC (storage)
* Connectors:
AC Input: Molex 5277-02A or equivalent device
DC Output: Molex 5273-08A or equivalent device
For Fan Use Only: Molex 5045-02A or equivalent device
* Dimensions: 12.7 x 7.62 x 3.86 cm at tolerance +/-0.4mm
Safety Standards
* Safety: UL 1950, CSA 22.2 No.234, VDE EN 60 950
* EMI: FCC Class B, EN55022B