English
Language : 

LXV100 Datasheet, PDF (1/2 Pages) List of Unclassifed Manufacturers – LED Power Supply
LED Power Supplies 100W
LXV100 series
LED Power Supply
Constant Voltage Power Supplies
LED POWER
next generation power
source
FEATURES
• High Efficiency 93%
• IP67 Waterproof
• Active PFC (Typical 0.96)
• OVP, SCP, OTP
• -35 to 70°C deg operation
• Wide Input 90-305VAC
option
• UL8750 recognised
• EN61347-1, -2-13 compliant
The LXV100 series of constant voltage LED power supplies from
Excelsys Technologies can deliver up to 100W of output power in an
extremely compact package size.
The LXV100 series of constant voltage power supplies provides a range of
output voltage solutions for specific LED requirements. With industry leading
efficiencies, and an extensive protection feature set, the LXV100 series
provides high reliability and high performance in a compact package
The LXV100 series carries the CE mark for safety and is also RoHS
compliant. For more details contact sales@excelsys.com
Model
Number
Output Output
Voltage Current
Input
Voltage
OVP
Max
OCP Efficiency
Hiccup
LXV100-012S
LXV100-024S
LXV100-036S
LXV100-042S
LXV100-048S
LXV100-054S
LXV100-081S
LXV100-105S
12V
24V
36V
42V
48V
54V
81V
105V
8.33A
4.05A
2.75A
2.25A
1.95A
1.75A
1.23A
0.95A
90-264VAC(3)
90-264VAC(3)
90-264VAC(3)
90-264VAC(3)
90-264VAC(3)
90-264VAC(3)
90-264VAC(3)
90-264VAC(3)
16V
34V
50V
57V
63V
75V
100V
140V
110-180%
110-180%
110-180%
110-180%
110-180%
110-180%
110-180%
110-180%
91.0%
93.0%
93.0%
93.0%
92.0%
93.0%
93.0%
93.0%
Input Specifications
Parameter
Input Voltage Range
Input Frequency Range
Input Current
Inrush Current
Power Factor
Conditions/Description
Universal Input. see Note 3
100VAC in, 100W output
220VAC in, 25°C, Cold Start
220VAC, 110VAC
Min
90
47
0.96
Nom
Max
264/305
63
1.20
65
0.99
Units
VAC
Hz
A
A
Output Specifications
Parameter
Conditions/Description
Line Regulation
Load Regulation
Voltage Accuracy
% of Vout
Ripple and Noise
20MHz Bandwidth. See Note 1
Dynamic Response
Output Deviation R/S : 1 A/uS
Settling Time Load : 25% ~ 75% full Load
Overshoot
Turn-on Delay
Measured at 220VAC and full load
Short Circuit Protection
Auto Recovery
Over Voltage Protection
Latching. See individual models OVP levels
OverTemperature Protection Internal Component Temperature
Min
Nom
Max
±1
±2
±5
1.5
5
10
10
3
110
Units
%
%
%
% pk-pk
%
mS
%
s
°C
General Specifications
Parameter
Isolation Voltage
Efficiency
Safety Agency Approvals
No load Power Dissipation
MTBF
Lifetime
Weight
Operating Temperature
Storage Temperature
Relative Humidity
Conditions/Description
Input to Output See Note 2
Input to Chassis
See individual models
UL8750, EN61347-1, -2-13
Measured at 120VAC and 220VAC
Telecordia SR-33, 25°C
25°C
Non-condensing (operating)
Min
Nom
Max
Units
1
3000
VAC
1500
VAC
93.0
%
1.5
W
2,000,000
Hours
100,000
Hours
950
g
-35
+70
°C
-40
+85
°C
10
100
%RH
Note 1.
Note 2.
Note 3.
Output connected in parallel with 0.1uF ceramic capacitor and 10uF electrolytic capacitor.
Primary to Secondary Isolation test not to be carried on power supply.
90-305VAC input voltage range available. Add Suffix “W” to part number e.g. LXV100-012SW
Europe/Asia
Excelsys Technologies Ltd
27 Eastgate Drive
Eastgate Business Park
Little Island, Cork, Ireland
IRELAND
t: +353 21 4354716
f: +353 21 4354864
e: sales@excelsys.com
North America
Excelsys Technologies
519 Interstate 30, #309
Rockwall, TX 75087
USA
t: (972) 771 4544
f: (972) 421 1805
e: salesusa@excelsys.com