English
Language : 

HRS2-SDC3V Datasheet, PDF (1/4 Pages) List of Unclassifed Manufacturers – Relay
HRS2(H) Relay
1.COIL DATA
1-1.Nominal Voltage
1-2.Coil Resistance
1-3.Operate Voltage
1-4.Release Voltage
1-5.Nominal Power Consumption
2.CONTACT DATA
2-1.Contact Arrangement
2-2.Contact Material
2-3.Contact Rating
2-4.Max. Switching Voltage
2-5.Max. Switching Current
2-6.Max. Switching Power
2-7.Contact Resistance ( Initial )
2-8.Life Expectancy Electrical
Mechanical
3.GENERAL DATA
3 VDC to 24 VDC
Refer to Table 1
Refer to Table 1
Refer to Table 1
150 to 360 mW
2 Form C
AuAg
1A 24 VDC / 120VAC
60 VDC / 120 VAC
2A
60 VA , 24W
100 mฆธ. at 6 VDC 1A
100,000 operations at nominal load
10,000,000 operations
3-1.Insulation Resistance
3-2.Dielectric Strength
3-3.Surge Strength
3-4.Operate Time
3-5.Release Time
3-6.Temperature Range
3-7.Shock Resistance
3-8.Vibration Resistance
3-9.Weight
3-10.Safety Standard
Min.100Mฆธ at 500 VDC
1,000VAC , 1min between open contact
1,500VAC , 1min between contact and coil
2,000 VAC ( 20 ฆฬs )
Max. 6ms
Max. 4ms
-30 to +60 กๆ
15G
10 - 55 Hz , Amplitude 1.5mm
5 gr.
UL NO. E164730
CSA NO. LR109368