High Temperature Thermostat
High temperature fuse H101(710°C)
H101
H101
49
(300)
Standard lead wires are 1.25 nickel, 300mm long.
(Ceramic tube type is available)
Features
1. It is very unique fuse of 710˚C/550˚C.
2. External dimensions are the same for all H101/102 models.
3. The fuse is housed in a ceramic cylinder case.
Ratings and Characteristics
Ty p e
H101
Fusing preset
temperature
710˚C ± 10˚C
Switching power
supply voltage
Switching capacity
Dielectric strength
(after fusing)
Commonly used 710˚C/200VAC 2A 1200VAC/sec
for 100/200V (resistance load) (between terminals)
Lead wire
1.25mm2
Nickel lead wire
Precautions for handling
1. When the current exceeds the rated value, it will activate at a lower temperature than the fusing preset
temperature. Check once again that the current is not exceeding the switching capacity.
2. Unexpected force or shock during transportation or mounting may cause breakage of the temperature
fuse. Furthermore, if the ambient temperature goes up, it may lead to an accidental fusing at a lower
temperature. So, be careful regarding the ambient temperature.
3. Keep the temperature sensor (protection tube) horizontal or pointing downward (lead wire will be at the
top) when in use. If it is used with the temperature sensor up, it may cause a malfunction.
4. Do not use in an environment where vibration or shock is constantly applied.
5. Watch for other heat sources, and try to avoid thermal interference. Be careful of fuse malfunction due
to unexpected other heat sources.
Caution
1. For storage, avoid high temperature places.
2. Ceramic protection cylinders tends to crack.
So, be careful when handling.
3. Do not use the fuse without the protection tube.
4. Keep the load current within the rated value.
In principle, the temperature fuse is
meant to be used as a fail safe measure.
The correct system design is such that
a thermostat is used for temperature
control and a temperature fuse activates
when the thermostat is broken.
NOTE: The specification in this brochure may be revised for improvement without notice. If you intend to purchase
our product in a large quantity, please be sure to mutually confirm the desired specifications.