English
Language : 

EZ240A12 Datasheet, PDF (1/2 Pages) List of Unclassifed Manufacturers – 5-18Amp 120/240, 480 Vac AC Output
Series EZ
5-18Amp • 120/240, 480 Vac • AC Output
• Low Leakage
• Quick Connect Terminals
• SCR Output
• 24V Control Available
(EZE Models)
The Series EZ SPST-NO AC output
relays offer a low profile package
with the convenience of quick con-
nect terminals. The Series EZ is the
preferred choice for replacement of
120V and 240V Electro-mechanical
relays. Output consists of an SCR
switch and is available in Zero-Cross
and Random Turn-On (Phase
Controlable) versions.
Manufactured in Crydom’s ISO 9001
Certified facility for optimum product
performance and reliability.
AC CONTROL (120Vac)
MODEL NUMBERS
(24Vac)
DC CONTROL (5Vdc)
OUTPUT SPECIFICATIONS ➀ (24Vdc)
Operating Voltage (47-63 Hz) [Vrms]
EZ240D5
24-280
EZ240A12
EZE240A12
EZ240D12
EZE240D12
24-280
EZ240A18
EZE240A18
EZ240D18
EZE240D18
24-280
EZ480A12
EZE480A12
EZ480D12
EZE480D12
48-660
Max. Load Current ➃ [Arms]
5
12
18
12
Min. Load Current, [mArms]
150
150
150
150
Transient Overvoltage [Vpk]
600
600
600
1200
Max. Surge Current, (16.6ms) [Apk]
40
150
200
150
Max. On-State Voltage Drop @ Rated Current [Vpk]
1.5
1.5
1.5
1.5
Thermal Resistance Junction to Case (RθJC) [˚C/W]
2.0
2.0
1.1
2.0
Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec]
95
95
170
95
Max. Off-State
Rated Voltage
Leakage
[mArms]
C➄urrent
@
0.1
0.1
0.1
0.1
Min. Off-State dv/dt @ Max. Rated Voltage [V/ µsec] ➁ 500
Max. Turn-On Time ➅
500
500
500
1/2 Cycle (DC Input), 10.0 msec (AC Input)
Max. Turn-Off Time
1/2 Cycle (DC Input), 40.0 msec (AC Input)
Power Factor (Min.) with Max. Load
0.5
0.5
0.5
0.5
EZ480A18
EZE480A18
EZ480D18
EZE480D18
48-660
18
150
1200
200
1.5
1.1
170
0.1
500
0.5
INPUT SPECIFICATIONS ➀
Nominal Voltage
5Vdc
MODEL NUMBERS
EZ240D05
Control Voltage Range
4-15 Vdc
DC CONTROL
5Vdc
5Vdc
EZ240D12 EZ480D12
EZ240D18 EZ480D18
3-15 Vdc 4-15 Vdc
24Vdc
EZE240D12
EZE240D18
EZE480D12
EZE480D18
15-32 Vdc
AC CONTROL
120Vac
24Vac
EZ240A12
EZ240A18
EZ480A12
EZ480A18
EZE240A12
EZE240A18
EZE480A12
EZE480A18
90-140 Vrms 18-36 Vrms
Max. Turn-On Voltage
4.0 Vdc
3.0 Vdc
4.0 Vdc
15.0 Vdc
90.0 Vrms 18.0 Vrms
Min. Turn-Off Voltage
1.0 Vdc
1.0 Vdc
1.0 Vdc
1.0 Vdc
10.0 Vrms 2.0 Vrms
Nominal Input Impedance
300 Ohms 300 Ohms 240 Ohms 1500 Ohms
10.6k Ohms 1.8k Ohms
Typical Input Current @ Nominal Voltage
13 mAdc 15 mAdc 15 mAdc 15 mAdc
10 mArms 10 mArms
GENERAL NOTES
©2002 CRYDOM CORP, Specifications subject to change without notice.
➀ All parameters at 25˚ C unless otherwise specified.
➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
➂ 240V, DC control models only, all others 2500Vrms.
➃ Heat sinking required, for derating curves see page 2.
➄ Off-State leakage for snubbered
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
version (suffix S) is 10.0 mArms.
➅ Turn-on time for random turn-on versions
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
is 0.1 msec (DC Control Models).
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
FastFax Document No.160
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
SERIES EZ.
GERMANY: +49 (0)180 3000 506
REV. 031802