English
Language : 

DPM3 Datasheet, PDF (1/2 Pages) List of Unclassifed Manufacturers – The DPM 3 is the largest in our sub-miniature series of meters but still uses the same miniaturisation techniques to produce a very compact instrument
DPM 3
3½ Digit Subminiature LCD Module
The DPM 3 is the largest in our sub-miniature series of meters but still uses the same miniaturisation techniques to produce a very compact
instrument. The snap-in integral bezel makes installation easy. For single rail operation, the DPM 3S features a built in negative rail generator,
enabling the meter to measure a signal referenced to its own power supply 0V.
11mm (0.43“) Digit Height
Programmable Decimal Points
Auto-zero
Auto-polarity
-+
200mV d.c. Full Scale Reading (F.S.R.)
SCALING
A potential divider may be used to alter the full scale
reading (F.S.R.) of the meter - see table.
+
NOTES
The meter will have to be
Ra
INPUT
1M
re-calibrated by adjusting
the calibration potentiometer
at the rear of the module.
Rb
-
3 IN HI
10nF
2 IN LO
Required F.S.R.
2V
20V
200V
2kV
note
200µA
2mA
20mA
200mA
Ra
910k
1M
1M
10M
0R
0R
0R
0R
Rb
100k
10k
1k
1k
1k
100R
10R
1R
NOTE
Ensure that Ra is rated for high voltage use.
Standard Meter
Single Rail Version
Specification
Accuracy (overall error) *
Linearity
Sample rate
Operating temperature range
Temperature stability DPM 3
DPM 3S
Supply voltage
DPM 3
DPM 3S
Supply current
DPM 3
DPM 3S
Input leakage current (Vin = 0V)
Min.
Typ.
0.1
3
0
200
100
7
9
3
5
150
250
1
* To ensure maximum accuracy, re-calibrate periodically.
Stock Number
DPM 3
DPM 3S
Max.
±1
50
Unit
% (±1 count)
count
samples/sec
°C
ppm/°C
14
7
V
µA
10
pA
DIMENSIONS All dimensions in mm (inches)
40.0 (1.57)
27.3 (1.07)
a b cd
a. 2.00 (0.08)
b. 6.00 (0.24)
c. 1.60 (0.06) max
d. 6.00 (0.24)
e. 2.54 (0.10)
f. 0.50 (0.02)
g. 6.00 (0.23)
h. 2.00 (0.08)
Panel cut-out
38.0 x 18.0 (1.50 x 0.71)
Panel thickness
1.0 to 2.5 (0.04 to 0.1)
ON BOARD SOLDER LINKS
e
f
11
g
1
h
11
1
REF
37.5 (1.48)
DP1 DP2 DP3 BAT
PANEL FITTING
Locate the meter by passing it through the front of the panel cut-out and gently push until the rear of the bezel is flush with the panel (DO NOT PUSH ON
THE LCD). The snap-in lugs will now automatically hold the meter firmly in position.