CX300 Datasheet, PDF (1/2 Pages) List of Unclassifed Manufacturers – Microprocessor Timer
EAGLE SIGNAL brand
Electronic Timers
CX300 Microprocessor Timer/Counter
Microprocessor based
timer/counter housed
in the industrial
standard CYCL-FLEX®
case
5
E
L
E T The CX300 is a microprocessor based timer/counter housed in a
CI
TM
RE
OR
N ST
II
standard 15 terminal CYCL-FLEX® plug-in case which allows easy
removal for programming changes and replacement. Time or count
operation, time range, and the type of start input switch operation are
programmed with 7 miniature rocker switches located inside the unit
housing.
CM
E
The front panel of the CX300 is a sealed membrane keypad which
R provides excellent protection for most industrial environments. The time
S or count setpoint is entered using the increment and decrement keys for
each digit position. The SET and ENT keys provide access to the
setpoint, as well as to the front panel programmable software functions.
These programmable functions control the pulse output length, setpoint
to zero or zero to setpoint cycle progress indication, and count input
scale factor. The software programming functions are indicated by
prompts to help the user program these functions without the need for
written instructions.
s Keypad lock function allows viewing of setpoint, but does not allow
unauthorized changes
s 4 1/2 digit (19999) liquid crystal display - .5 inch high digits
s Annunciators (right of the display) flash to indicate timing or counting
s Two form C instantaneous contacts and two form C programmed
contacts
s Five time ranges from 19.999 sec. to 199 hr.: 59 min.
s Three count rate input rate speeds are programmable with a max.
count display of 19999 - can be extended via count input scale
factor
s 24, 120, or 240 VAC operations
s Count input available for 120 volt AC or low voltage AC/DC
operations
s When programmed as timer, count input circuit serves as time inhibit
(without resetting the unit)
s Non-volatile memory data retention
®
RECOGNIZED
®
CERTIFIED
SPECIFICATIONS
Time/Count Ranges:
Sym.
1
2
3
4
5
6
7
8
Maximum Minimum
Range
Setting
Count
Rate
19999 Cts.
19999 Cts.
19999 Cts.
199.99 Sec.
1999.9 Sec.
19.999 Sec.
199 Min.: 59 Sec.
199 Hr.: 59 Min.
1 Ct.
1 Ct.
1 Ct.
.01 Sec.
.1 Sec.
.001 Sec.
1 Sec.
1 Min.
4000/Sec. 12-50 VDC Count Input
500/Min. AC or DC
5000/Min. AC or DC
Operating Voltage/Frequency: A6 - 120 VAC, 50/60 Hz
B6 - 240 VAC, 50/60 Hz
Z6 - 24 VAC, 50/60 Hz
Time Inhibit/Count Line Terminals B & C:
CX311/CX341 - 12-50 VDC or 20-28 VAC, 50/60 Hz
CX312/CX342 - 120 VAC, 50/60 Hz or 120 VDC
Setting Accuracy: Time: ±0.1% or 50 ms, whichever is larger (0˚ to 60˚C)
Count: 100%
Repeat Accuracy:
Time: ±0.1% or 35 ms, whichever is larger (0˚ to 60˚C)
Count: 100%
Reset Time: 30 ms following voltage removal from simulated clutch input
(CR1)
Power on Response: 300 ms max. after voltage applied to terminal 11
Operating Temperature: +32˚ to +140˚F (0˚ to +60˚C)
Output Rating: Relay: 10 amp (resistive), 120 VAC
Mechanical Life: 20 million operations
Electrical Life: contingent upon controlled load
Solid State: 1 amp, 0-264 VAC, VDC
Vibration: Unit function is unaffected by 2.5G sinusoidal vibration magni-
tude in both directions of the perpendicular mounting axes imposed from
10 to 100 Hz
Static Discharge: Unit function is unaffected by a constant 3600 volt peak,
60 Hz discharge applied to the grounded front plate at a relative humidity
of less than 25%
Approvals: UL Recognition E96337
CSA Certification LR26861
5.34 DANAHER SENSORS & CONTROLS