English
Language : 

CLD2ET1CM24 Datasheet, PDF (1/4 Pages) List of Unclassifed Manufacturers – Conductive Sensors 2-point level controller
Conductive Sensors
2-point level controller
Type CL with teach-in
• Conductive level controller
• Teach-in of sensitivity – operating resistance from
220Ω to 220KΩ
• For filling or emptying applications
• Low-voltage AC electrodes
• Easy installation on DIN rails or with 11 pin circular
plug
• Rated operational voltage:
24 VAC/DC, 115 VAC or 230 VAC
• Output 2x5A/250 VAC DPDT relay
• LED indication for: Calibration, faulty operation and
relay status
Product Description
Ordering Key
µ-Processor based level
controller for liquids with a
wide sensitivity range (like
sewage water, chemicals, salt
water etc.).
Max./min. control of charging/
discharging. The sensitivity is
adjustable by means of the
teach-in function.
2 X 5A DPDT relay output.
Type
DIN rail mounting
Inputs
Function
Adjustment
Outputs
Relay versions
Power supply
Type Selection
Mounting
Relay
Ordering no.
Supply: 24 VAC/DC
Ordering no.
Supply: 115 VAC
DIN-rail
DPDT
CLD2ET1CM24
CLD2ET1C115
11-p circular plug
CLP2ET1CM24
CLP2ET1C115
CLD2ET1CM24
Ordering no.
Supply: 230 VAC
CLD2ET1C230
CLP2ET1C230
Specifications
Rated operational voltage (UB)
Pin 2 & 10
230
115
924
Rated insulation voltage
Rated impulse withstand
voltage
Rated operational power
AC supply
AC/DC supply
Delay on operate (tV)
Outputs
Rated insulation voltage
Relay Rating (AgCdO)
Resistive loads
Small induc. Loads
Mechanical life (typical)
AC1
DC1
or
AC11
DC13
Electrical life (typical)
AC1
Level probe supply
Level probe current
Sensitivity
195 to 265 VAC, 45 to 65 Hz
98 to 132 VAC, 45 to 65 Hz
19.2 to 28.8 VAC/DC
<2.0 kVAC (rms)
4 kV (1.2/50 µs) (line/neutral)
5 VA
5 VA / 5 W
< 300 mS
250 VAC (rms) (cont./elec.)
µ (micro gap)
5 A / 250 VAC (2500 VA)
1 A / 250 VDC (250 W)
5 A 25 VDC (250 W)
0,4 A 250 VAC
0,4 A / 30 VDC
≥ 30 x 106 operations
@ 18’000 imp/h
> 250’000 operations
Max. 12 VAC
Max. 2.5 mA
220Ω to 220KΩ
Factory preset: 47KΩ
Dielectric voltage
Rated impulse withstand volt.
Operating frequency (f)
Relay output
Response time
Environment
Overvoltage category
Degree of protection
Pollution degree
Temperature
Operating
Storage
Housing material
Weight
AC supply
AC/DC supply
Approvals
CE marking
>2.0 KVAC (rms)
(contacts / electronics)
4 kV (1.2/50 µS) (contacts /
electronics) (IEC 664)
1 HZ
1 s (3.5 s with filter)
III (IEC 60664)
IP 20 /IEC 60529, 60947-1)
2 (IEC 60664/60664A,
60947-1)
-20º to +70ºC (-4º to + 158º)
-50º to +85ºC (-58º to +185ºF)
NORYL SE1, light grey
200 g
125 g
UL508, CSA
Yes
Specifications are subject to change without notice (08.12.2005)