English
Language : 

BK-1 Datasheet, PDF (1/2 Pages) List of Unclassifed Manufacturers – Printed Circuit Board Fuses
Printed Circuit Board Fuses
PC-Tron Series
Description
• Non-Time Delay
• Ideal for high voltage DC applications
• Board washable
• Optional mounting socket available (PCS)
• Available in different lead configurations
Agency Information
• UL Recognized - File E19180, Guide JDYX2
• CSA Certified - File 42731, Class 1422-01
AC TIME-CURRENT CHARACTERISTICS
% of Amp Rating
Opening Time
100%
4 hours minimum
200%
10 second maximum
Ordering
• Specify packaging code and product code
(i.e., BK/PCB-1/2)
DC Application
The PC-Tron subminiature fuse is UL Recognized for
DC supplementary overcurrent protection to provide
individual protection for components or internal circuits in
equipment. Suitability for a specific application is
dependent on time constants and capacitance values. It
is the responsibility of the customer to evaluate the
information provided for applicability to their particular
application.
Dimensions
⁄mm
(inches)
± .005"
Dimensional Data: All tolerances ± .13 mm
Mounting Socket
• Available as option. (Specify catalog number BK/PCS
(100-in) and short fuse lead length — PCC or PCE)
Socket (PCS)
.300"
(7.62mm)
.200"
(5.08mm)
.095"
(2.41mm)
.030"
(2.41mm)
.290"
(7.37mm)
.12" ± .010"
(3.05mm ± 0.25mm)
Product Code /
Amp Rating
PCB - 1/2, 3/4, 1, 1-1/2, 2, 2-1/2
PCB - 3
PCC - 1/2, 3/4, 1, 1-1/2, 2, 2-1/2
PCC - 3
PCD - 5
PCE - 5
PCF - 1/2, 3/4, 1, 1-1/2, 2, 2-1/2
PCF - 3
PCG - 5
PCH - 1/2, 3/4, 1, 1-1/2, 2, 2-1/2
PCH - 3
PCI - 5
SPECIFICATIONS
Lead
Voltage
AC
Length
Rating AC Interrupting
Full - 0.750" (straight)
250V
50A @ 250V
10kA @ 125V
Full - 0.750" (straight)
250V
50A @ 250V
Short 0.100" (straight)
250V
50A @ 250V
10kA @ 125V
Short 0.100" (straight)
250V
50A @ 250V
10kA @ 125V
Full - 0.750" (straight)
125V 10kA @ 125V
Short 0.100" (straight)
125V
10kA @ 125V
0.475"
250V
50A @ 250V
10kA @ 125V
0.475"
250V
50A @ 250V
10kA @ 125V
0.475"
125V 10kA @ 125V
0.125"
250V
50A @ 250V
10kA @ 125V
0.125"
250V
50A @ 250V
10kA @ 125V
0.125"
125V 10kA @ 125V
Voltage
Rating DC
450V
350V
450V
350V
250V
250V
450V
350V
250V
450V
350V
250V
DC Interrupting
Min.
Max.
300
5900A
300
4400A
300
5900A
300
4400A
300
4200A
300
4200A
300
5900A
300
4400A
300
4200A
300
5900A
300
4400A
300
4200A
Device designed to carry rated current for four hours minimum. An operating current of 80% or less of rated current is recommended, with further derating required at
elevated ambient temperatures.