English
Language : 

AC558 Datasheet, PDF (1/2 Pages) List of Unclassifed Manufacturers – 5 TO 500 MHz TO-8 CASCADABLE AMPLIFIERS
2/99
AC558
AC559
5 TO 500 MHz
TO-8 CASCADABLE AMPLIFIERS
Typical Values
High Dynamic Range . . . . . . . . . . . . . . . . . . .
High Power Output . . . . . . . . . . . . . . . . . . . . .
High Third Order I.P. . . . . . . . . . . . . . . . . . . . .
High Performance Thin Film
Available in Surface Mount
AC558
+114 dBm
+19.0 dBm
+32.0 dBm
AC559
+117 dBm
+22.0 dBm
+35.0 dBm
SPECIFICATIONS*
Parameter
Frequency (Min.)
Small Signal Gain (Min.)
Gain Flatness (Max.)
Noise Figure (Max.)
AC558
AC559
SWR (Max.)
Input/Output
Power Output (Min.)
@ 1 dB comp.
.
AC558
AC559
DC Current (Max.)
AC558
AC559
Typical
5-600 MHz
11.0 dB
±0.2 dB
<5.2 dB
<5.7 dB
<1.6:1
+19.0 dBm
+22.0^ dBm
65.0 mA
88.0 mA
Guaranteed
0 to 50° C -55 to +85° C
5-500 MHz
10.5 dB
5-500 MHz
10.0 dB
±0.5 dB
±0.7 dB
6.0 dB
6.5 dB
6.5 dB
7.0 dB
1.8:1
1.9:1
+18.0 dBm
+21.0^ dBm
68.0 mA
92.0 mA
+17.5 dBm
+20.5^ dBm
71.0 mA
96.0 mA
* Measured in a 50-ohm system at +15 Vdc unless otherwise specified.
^ 0.5 dBm less below 200 MHz.
INTERMODULATION PERFORMANCE
Typical @ 25° C; 200 MHz
Second Order Harmonic Intercept Point . . . . .
Second Order Two Tone Intercept Point. . . . . .
Third Order Two Tone Intercept Point. . . . . . . .
AC558
+56 dBm
+50 dBm
+32 dBm
AC559
+55 dBm
+49 dBm
+35 dBm
ABSOLUTE MAXIMUM RATINGS
Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -62 to 125° C
Maximum Case Temperature . . . . . . . . . . . . . . . . . . . . . . . .
+125° C
Maximum DC Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
+19 Volts
Maximum Continuous RF Input Power . . . . . . . . . . . . . . . .
+13 dBm
Maximum Short Term Input Power (1 Minute Max.) . . . . . . 100 Milliwatts
Maximum Peak Power (3 µsec Max.) . . . . . . . . . . . . . . . . . .
0.5 Watt
Burn-in Temperature (AC558/AC559) . . . . . . . . . . . . . . . . . +105° C/+85° C
Thermal Resistance1 (θjc; AC558) . . . . . . . . . . . . . . . . . . . . +37° C/Watt
Thermal Resistance1 (θjc; AC559) . . . . . . . . . . . . . . . . . . . . +37° C/Watt
Junction Temperature Rise Above Case (Tjc; AC558) . . . .
+37.4° C
Junction Temperature Rise Above Case (Tjc; AC559) . . . .
+50.3° C
1 Thermal resistance is based on total power dissipation.
AC558/AC559
TO-8 Package for Amplifiers
0.450 (11.43)
DIA.
0.208 (5.28)
MAX.
0.185 ± 0.015
(4.70 ± 0.38)
50 OHM INPUT
0.504 (12.80)
DIA.
0.025
(0.64)
0.018
(0.46
± 0.002
± 0.05)
DIA.
PIN
(4) PLCS
GROUND
50 OHM OUTPUT
+DC VOLTAGE
0.300
(7.62)
DIA. B.C.
0.033 (0.84)
0.031 (0.79)
45° ± 3°
AS558/AS559
SMTO-8 Package for Amplifiers
DC BIAS
DETAIL A
(NO SCALE)
0.016 ± 0.002
0.010 ± 0.002
0
50 Ω INPUT
0.250
(6.35)
0.450
(11.43)
GND
SEE
DETAIL "A"
0
0.075
(1.91)
0.200
(5.08)
0.350
(8.89)
0.450
(11.43)
0.010 (TYP.)
(0.25)
0.016 ± 0.002
(0.41 ± 0.05)
(4) PLCS
50 Ω OUTPUT
0.040 ± 0.012
(1.02 ± 0.30)
(4) PLCS
0.050
(1.27)
(4) PLCS
0.100
(2.54)
(4) PLCS
0.031
(0.79)
0.031
(0.79)
45°
0.008
0.012
0.170
(4.32)
0.008 ± 0.001
(0.20 ± 0.03)
DIMENSIONS ARE IN INCHES (MILLIMETERS)
146
408-522-3838 • Fax: 408-522-3839 • Check for updates: www.cougarcorp.com
2005/2006