English
Language : 

3216CP Datasheet, PDF (1/2 Pages) List of Unclassifed Manufacturers – 3216CP Series Circuit Protector
Description
• Surface mount circuit protector
• Compatible with reflow and wave solder
• Excellent environmental integrity
• One time positive disconnect
• Ampere rating marked and oriented facing up in carrier
• Solder-free design provides excellent temperature
cycling
• Heat and shock tolerant
ELECTRICAL CHARACTERISTICS
% of Amp Rating
Opening Time
100%
4 Hours Minimum
250%
10 Seconds Maximum
600%
1 millisecond typical
Agency Information
• UL Recognition Guide & File numbers: JDYX2 & E19180.
• CSA Certification Record No: 053787 C 000 & Class No:
1422 30.
Environmental Data
• Thermal Shock: MIL-STD-202, Method 107, Test
Condition B (-65°C to 125°C)
• Vibration: MIL-STD-202, Method 204, Test Condition C
(55 to 2000 Hz, 10G)
• Moisture Resistance: MIL-STD-202, Method 106,
10 day cycle
• Solderability: ANSI/J-STD-002, Test B
Soldering Method
• Wave Solder: 260°C, 10 sec max.
• Infrared Reflow: 260°C, 30 sec max.
Ordering
• Specify product code and packaging code
Chip™ Fuses
3216CP Series Circuit Protector
Dimensions
⁄mm
(inches)
Drawing Not to Scale
Land Pattern
Product Code
3216CP-250mA
3216CP-375mA
3216CP-500mA
3216CP-750mA
3216CP-1A
3216CP-1.5A
3216CP-2A
3216CP-2.5A
3216CP-3A
3216CP-4A
3216CP-4.5A
3216CP-5A
Voltage
Rating
(DC)
24V
24V
24V
24V
24V
24V
24V
24V
24V
24V
24V
24V
SPECIFICATIONS
Interrupting
Resistance
Rating*
(ohms)**
24V DC
Typ.
35A
4.50
35A
1.80
35A
1.15
35A
0.75
35A
0.168
35A
0.098
35A
0.063
35A
0.046
35A
0.037
35A
0.019
35A
0.014
35A
0.013
* DC Interrupting Rating (Measured at designated voltage, time constant of less than 50 microseconds, battery source)
** DC Cold Resistance (Measured at 10% of rated current)
† Typical Melting I2t (Measured with a battery bank at rated DC voltage, 10x-rated current, time constant of calibrated
circuit less than 50 microseconds)
‡ Typical Voltage Drop (Measured at rated current after temperature stabilizes)
• It is recommended that fuses be mounted with glass (blue) side facing up.
• Device designed to carry rated current for four hours minimum. An operating current of 80% or less of rated current is
recommended, with further derating required at elevated ambient temperatures.
Typical
Melt
I2t†
0.000084
0.0002
0.0019
0.00095
0.007
0.029
0.049
0.112
0.165
0.189
0.328
0.619
Typical
Voltage
Drop (V)‡
1.4
0.73
0.66
0.63
0.2
0.18
0.16
0.14
0.13
0.11
0.1
0.09