22NAB12 Datasheet, PDF (1/4 Pages) List of Unclassifed Manufacturers – 3-phase bridge rectifier +braking chopper +3-phase bridge inverter | |||
|
SKiiP 22 NAB 12 - SKiiP 22 NAB 12 I
Absolute Maximum Ratings
Symbol Conditions 1)
Inverter & Chopper
VCES
VGES
IC
ICM
IF = âIC
IFM = âICM
Theatsink = 25 / 80 °C
tp < 1 ms; Theatsink = 25 / 80 °C
Theatsink = 25 / 80 °C
tp < 1 ms; Theatsink = 25 / 80 °C
Bridge Rectifier
VRRM
ID
IFSM
I2t
Theatsink = 80 °C
tp = 10 ms; sin. 180 °, Tj = 25 °C
tp = 10 ms; sin. 180 °, Tj = 25 °C
Tj
Tstg
Visol
AC, 1 min.
Values
1200
± 20
23 / 15
46 / 30
24 / 17
48 / 34
1500
25
700
2400
â 40 . . . + 150
â 40 . . . + 125
2500
Units
V
V
A
A
A
A
V
A
A
A2s
°C
°C
V
Characteristics
Symbol Conditions 1)
IGBT - Inverter & Chopper
VCEsat
td(on)
tr
td(off)
tf
Eon + Eoff
Cies
Rthjh
IC = 15 A Tj = 25 (125) °C
VCC = 600 V; VGE = ± 15 V
IC = 15 A; Tj = 125 °C
Rgon = Rgoff = 82 â¦
inductive load
VCE = 25 V; VGE = 0 V, 1 MHz
per IGBT
Diode 2) - Inverter & Chopper
VF = VEC
VTO
rT
IRRM
Qrr
Eoff
Rthjh
IF = 15 A Tj = 25 (125) °C
Tj = 125 °C
Tj = 125 °C
IF = 15 A, VR = â 600 V
diF/dt = â 400 A/µs
VGE = 0 V, Tj = 125 °C
per diode
Diode - Rectifier
VF
Rthjh
IF = 35 A, Tj = 25 °C
per diode
Temperature Sensor
RTS
T = 25 / 100 °C
Shunts (SKiiP 22 NAB 12 I)
Rcs(dc)
5 % 4)
Rcs(ac)
1%
Mechanical Data
M1
Case
case to heatsink, SI Units
mechanical outline see page
B 16 â 8
min. typ. max. Units
â 2,5(3,1) 3,0(3,7) V
â
55
110 ns
â
45
90
ns
â
400 600 ns
â
70
100 ns
â
4,0
â
mJ
â
1,0
â
nF
â
â
1,4 K/W
â 2,0(1,8) 2,5(2,3) V
â
1,0
1,2
V
â
53
73 mâ¦
â
16
â
A
â
2,7
â
µC
â
0,6
â
mJ
â
â
1,7 K/W
â
1,2
â
V
â
â
1,6 K/W
1000 / 1670
â¦
16,5
mâ¦
10
mâ¦
2
â
2,5 Nm
M2
MiniSKiiP 2
SEMIKRON integrated
intelligent Power
SKiiP 22 NAB 12
SKiiP 22 NAB 12 I 3)
3-phase bridge rectifier +
braking chopper +
3-phase bridge inverter
Case M2
UL recognized file no. E63532
⢠specification of shunts and
temperature sensor see part A
⢠common characteristics see
page B 16 â 4
1) Theatsink = 25 °C, unless
otherwise specified
2) CAL = Controlled Axial Lifetime
Technology (soft and fast
recovery)
3) With integrated DC and/or AC
shunts
4) accuracy of pure shunt, please
note that for DC shunt no
separate sensing contact is
used.
© by SEMIKRON
000131
B 16 â 53
|
▷ |