English
Language : 

10CPV120 Datasheet, PDF (1/2 Pages) List of Unclassifed Manufacturers – Phase Control Modules
Series CPV
Phase Control Modules
• 120 & 240 Vac Models
• 0-5 Vdc Phase Control
Models CPV120 and CPV240 auxiliary
function modules provide control of the
phased turn-on of a solid state relay, in
response to the application of a 0-5 Vdc
control signal. They must be used with
Crydom Series 1 (-10) random turn-on
solid state relays. Consult factory about
use with 480 Vac loads. For a com-
plete set (control module and solid state
relay) order 10CPV120, 25CPV120, etc.
Manufactured in Crydom’s ISO 9002
Certified facility for optimum product
performance and reliability.
MODEL NUMBERS
RELAY OUTPUT SPECIFICATIONS Œ
Operating Voltage Range (47-63 Hz) [Vrms]
Load Current Range Ž [Arms]
120 Vac
240 Vac
Transient Overvoltage [Vpk]
Max. Surge Current, (16.6ms) [Apk]
Max. On-State Voltage Drop @ Rated Current [Vpk]
Thermal Resistance Junction to Case [RθJC] °C/W
Maximum I2 t for Fusing, (8.3 msec.) [A2sec]
Max. Off-State Leakage Current @ Rated Voltage [mArms]
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]
Max. Turn-On Time [msec]
Max. Turn-Off Time
Power Factor (Min.) with Max. Load
10CPV120 25CPV120 40CPV120
10CPV240 25CPV240 50CPV240 75CPV240 90CPV240
.04-10
120
1.6
1.48
60
10.0
500
0.02
1/2 cycle
0.5
90-140 (120 Vac Models)
180-280 (240 Vac Models)
.04-25
.04-50
.04-75
400 (120 Vac models)
600 (240 Vac models)
250
625
1000
1.6
1.6
1.6
1.02
0.63
0.31
260
1620
4150
10.0
10.0
10.0
500
500
500
0.02
0.02
0.02
1/2 cycle
0.5
1/2 cycle
0.5
1/2 cycle
0.5
.04-90
1200
1.6
0.28
6000
10.0
500
0.02
1/2 cycle
0.5
CONTROL MODULE INPUT SPECIFICATIONS Œ
Logic Supply Range (Terminal 3A)
Typical Supply Current
Control Voltage Range (Terminal 3B)
Nominal Control Input Impedance
Min. Turn-Off Voltage
DC CONTROL
3.5-10Vdc
1.6mA @ 5Vdc
0-5 Vdc
1500 Ohms
1.0
CONTROL MODULE OUTPUT (Terminal 4B – Input to Relay) Œ
Max. Off-State Operating Voltage
36 Vdc
Max. Load Current (Sink)
3.0 mA
Max. On-State Voltage @ 3mA
0.5 Vdc
Max. Off-State Leakage @ 10Vdc
1.0 µAdc
GENERAL NOTES
Œ All parameters at 25ºC unless otherwise specified.
 Off-State dv/dt test method per
EIA/NARM standard RS-443,
paragraph 13.11.1
Ž Heat sinking required (Relay Only),
see Series 1 data sheet.
FastFax Document No. 203
SERIES CPV.040898, PAGE 1 OF 2
©1998 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: (800) 8 CRYDOM • (800) 827-9366 • (619) 715-7200 • fax (619) 715-7280
9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: sales@crydom.com
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
UK: (44)1202 812300 • fax (44)1202 812340
85, Condor Close, Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY: (49)871 935405 • fax (49)871 935407, Aussere Parkstr.5, D-84032 Altdorf, Germany