English
Language : 

E-1048-8D Datasheet, PDF (3/4 Pages) ETAL Group – Integral power electronics provide a wear-resistant switching function, insensitive to shock, vibration and dust
Smart Power Relay E-1048-8D...
Typical time/current characteristics (TA = 25 °C)
Trip curve 1 “ENTRYprotect”
1 A, 2 A, 3 A, 5 A, 7,5 A and 10 A (standard 200 ms)
1000
100
10
Connection diagrams DICE version
C0 Control Input IN+
LINE (+)
DC 12 V/24 V
control input
1…10 mA
+
IN+
1
max. overload
0.1
0
1
2
(typically 60 A) I (A)
typ. 1.3 x IN
... times rated current IN
Trip curve 2 “ENTRYprotect”
15 A, 20 A, 25 and 30 A (standard 200 ms)
1000
100
LOAD (+) GND
C1 (Control Input IN-)
LINE (+)
DC 12 V/24 V
control input
IN-
1…10 mA
10
1
LOAD (+) GND
5
0.1
0
max. overload
1
2
typ. 1.3 x IN
(typically 200 A) I (A)
...times rated current IN
Preferred types
Preferred types
E-1048-8D4-C0A0-4U3-
Standard current ratings (A)
1 2 3 5 7.5 10 15 20
x
x
x
x
x
x
x
x
Pin selection DICE version (4 pin)
E-1048-8D DICE version
1
LINE + (30) 2 US (DC 12 V/24 V)
3
IN (86) 4 control input
5
GND (31) 6 ground US
LOAD (88a) 8 load output
2
(30)
6
4
(31) (86)
(88a) 8
1646
All dimensions without tolerances are for reference only. In the interest of improved design,
performance and cost effectiveness the right to make changes in these specifications without
notice is reserved. Product markings may not be exactly as the ordering codes. Errors and
omissions excepted.
www.e-t-a.de
3