EXR10 Datasheet, PDF (1/3 Pages) ETAL Group – Diagnostic functions regarding current, voltage or wiring can individually be adjusted to applications
Electronic Relay with Extra Functions - EXR10
Description
The electronic relay EXR10 (Electronic eXtra Relay) is a solid state
relay combining various extra functions in a single unit. These include:
l Solid state relay with diagnostic functions such as low voltage
monitoring, wire break detection and current-proportional voltage
output
l Electronic overcurrent protection
The relay fits into 4-pole or 7-pole standard automotive relay sockets
to ISO 7588 (ISO Mini). It is suitable for system voltages of DC 12 V
and DC 24 V (operating range DC 9...32 V) and can switch currents
between 1 and 30 A.
For remote switching and protection of loads, two separate
components had up to now often to be connected in the load circuit
as a functional unit:
EXR10
l An electro-mechanical relay or solid state relay which is powered
via the control cable and then closes the circuit by means of the
integral contact or power semi-conductor.
Technical data (25 °C)
l An additional protective element (circuit breaker or fuse) providing Voltage supply LINE+
line or equipment protection in the event of a failure.
System voltage
UB
12/24 V DC
The EXR10 combines diagnostic functions with overcurrent protection in
a single component, thus minimising the number of connections in the
circuit and reducing the failure risk. In addition the ETR10 is remotely
resettable after overload tripping if an overload in the load path has
caused the relay to switch off.
Operating voltage
9...32 V DC
Closed current1)2)
OFF
150 µA
Load circuit LOAD
Load output MOSFET, high side
switching (HSS)
Applications
The EXR10 is suitable for all applications in DC 12 V and DC 24 V
Load types resistive, inductive
and capacitive
Protective function short circuit proof, overload
protection temperature
disconnection
on-board electrical systems where magnetic valves, motors or lamps
have to be switched and protected:
l Road vehicles (passenger cars, bicycles, trucks, buses, working
vehicles and emergency cars, special vehicles)
l Construction vehicles and agricultural vehicles
l Rail vehicles
l Watercraft (ships, sailing boats, motor yachts etc.)
l Industrial process control and production technology
Current rating 3)
IN
Short circuit current IK max.
free-wheeling diode
Voltage drop
UON max.
1...30 A
70 A (IN up to 10 A) L/R = 2ms
250 A (IN from 15 A) L/R = 2ms
integral
in mV (at IN in A)
IN
1 2 3 5 7.5 10 15 20 25 30
UON 50 55 60 80 90 110 70 90 120 140
Control input IN+
Features and Benefits
Control voltage
ON
8.5…32 V DC
OFF
0…5 V DC
l Diagnostic functions regarding current, voltage or wiring can
individually be adjusted to applications
Control current1) 1…10 mA (8.5 … 32 V DC)
Rising edge
< 5 ms
5
l Plus-switching (positive control) solid state relay with high side Status outputs (optional)
switch (HSS) for load currents between 1 A and 30 A
l Integral protection against short circuit and overload in the load
circuit
l Remotely resettable upon detection and disconnection of
overcurrent by means of the protective function
l Silent switching
l Wear-free and robust design, insensitive to shock, vibration and
dust (no mechanical contacts)
l Very low closed current and switching current consumption
l Fits into standard ISO Mini automotive relay sockets
Outputs S1 and S2 MOSFET low side switch (LSS)
cont. current
IS1,S2 max
500 mA
Current-proportional U(I)
0...IN: 0...5 V ± 0,5 V
output S3
> IN: 5...7 V
PWM(I)
0...IN: 0...75 % ± 7,5 %
> IN: 76...100 %
Cont. current
IS3 max
5 mA
General data
Reverse polarity
control circuit yes
protection
load circuit no (due to free-wheeling diode)
Switching times1)
tON
4 ms
tOFF
4 ms
Temperature range
-40° C to +85° C
Approvals
Degree of protection enclosure IP30 (not sealed)
IP55 (sealed)
Authority
Approval mark
Regulation
Dimensions
ISO Standard Mini
plugged-in
30 × 30 × 40 mm
KBA
E1
ECE R 10
incl. contacts
Mass1)
not sealed
sealed
30 × 30 × 51.6 mm
25 g (IN up to 10 A)
30 g (IN 15 A up to 20 A)
75 g (IN 25 A or 30 A)
1) typically
2) with status outputs 300 µA
3) > 20 A only with high-quality or new sockets
1646
www.e-t-a.de
1