English
Language : 

E-1073 Datasheet, PDF (1/6 Pages) ETAL Group – Battery and cable protection for all types of vehicle (including electric), battery powered systems.
Battery Isolation Switch E-1073-437
Description
Single pole circuit breaker type 437 featuring an additional electronic
function module which limits the duration of the supply to the remote
disconnect and re-connect coils, avoiding damage in the event
of unusual operating circumstances. Available with undervoltage
monitoring option to protect batteries from the effects of deep
discharge, status output for undervoltage, auto reset feature.
Typical applications
Battery and cable protection for all types of vehicle (including electric),
battery powered systems.
Ordering information
E-1073-437
Type No.
Technical data of circuit breaker
E-1073 control unit for type 437 with remote control
Voltage rating
0 DC 12 V
see type 437
2
1 DC 24 V
Control mode
1 ON/OFF control input
Technical data – Electronic module
00 without additional function
02 with undervoltage protection and status output
Voltage rating
DC 24 V
2 ON and OFF buttons
33 with control current supply and ON/OFF test input
Circuit Breaker
437 single pole circuit breaker (double pole upon request)
Enclosure design (optional)
blank without enclosure
B3 moulded housing
Terminal design
K60 straight flat screw terminal
(for use without housing)
Voltage rating range
Temperature range
electronic control unit
Operating current
ON 18 - 32 V
OFF 16 - 32 V
Correct switching performance is not
guaranteed if the voltage falls below the
minimum value.
-40...+80 °C (-40...+176 °F)
ON approx. 15 A
OFF approx. 20 A
K12 screw terminal, angled 90°
Excitation time
ON typically 100 ms
(for use with B3 or B35)
OFF typically 20 ms
Mounting
5 mounting brackets for
surface mounting
Characteristic curve
06 fast trip
07 delayed trip
Auxiliary contacts
Si01 one N/C and two N/O
Remote ON and OFF
operation
FC12 DC12V, remote ON/OFF
FC24 DC24V, remote ON/OFF
Suffix
Switching frequency
Power consumption
of electronic control unit
Control inputs
voltage
ON (high)
OFF (low)
power consumption
0.1 Hz max.
typically < 1 mA
(when switched off or button operated)
E-1073-.1..:
»E/A« (ON/OFF), »U-AUS«
(undervoltage protection OFF), »A-W« (auto reset)
E-1073-.2..:
»T-EIN« (button ON), »T-AUS« (button OFF)
max. 32 V
>8V
<3V
DC 24 V: typically 5 mA
173027 standard
EMC
according to DIN 40839/ISO 7637
Current ratings
80 A, 100 A, 120 A,
160A, 180 A, 200 A,
Reverse polarity
protection
If polarized incorrectly, the
circuit breaker will trip after a few seconds.
240 A
Undervoltage protection optional with E-1073-.1..
switching thresholds DC 24 V: 22.8 V ± 0.2 V
E-1073-1 1 02 - 437-B3 -K60-5 - 06 -Si01-FC12 - 173027 - 240 A
hysteresis
typically 0.5 V
ordering example
trip time
typically 40 sec
The exact part number required can be built up from the table of choices shown
above. Ordering references for optional features should be omitted if not required.
Undervoltage status output »UST«, optional with E-1073-.1..
transistor output
minus switching
current load
corresponding to 2 W lamp load, short-
circuit proof
Control current supply »+US2«, with E-1073-.2.. for T-EIN/T-AUS
May be connected to 20 control inputs.
Noise-voltage proof, short-circuit proof
Terminals
control terminals
blade terminals 6.3x0.8 mm
Mass
approx. 2,000 g without enclosure
1646
www.e-t-a.de
1