English
Language : 

482-G Datasheet, PDF (1/4 Pages) ETAL Group – Extra low voltage wiring systems on all types of vehicles for land, sea and air, battery powered machines, process control
High Performance Thermal Circuit Breaker 482-...
Description
Single pole compact high performance thermal circuit breaker with
tease-free, trip-free, snap action mechanism and push/pull on/off
manual actuation (M-type TO CBE to EN 60934). An indicator band
on the push button clearly shows the tripped/off position. Threadneck
panel mounted in tracked vehicle and aircraft/general purpose versions,
with optional auxiliary contacts.
Typical applications
Extra low voltage wiring systems on all types of vehicles for land, sea
and air, battery powered machines, process control.
1
482
without aux. contacts
with aux. contacts
Ordering information
Type No.
482 single pole thermal circuit breaker
Mounting
G threadneck panel mounting
Threadneck design
1 M 12x1 nickel plated
2 M 12x1 black
Hardware - washer for threadneck
0 without hardware
1 corrugated washer 12/15, fitted
Hardware - hex nut for threadneck
0 without hardware
1 hex nut M12x1 nickel plated
2 hex nut M12x1 black
Terminal design (main terminals)
K1 screw terminals with metric thread M4
Characteristic curve
M1 thermal 1.15-1.4 IN
Terminal screws
A flat head screw M4x6, ISO 1580, fitted
F Phillips screw M4x6 (ISO 7045), bulk shipped
Z without
Terminal washers
0 without lock washer
1 lock washer DIN 137-B4, fitted
6 lock washer DIN 137-B4, bulk shipped
Auxiliary contact
S0 without auxiliary contacts
S1 with auxiliary contact (NC)
Current ratings
0.1...50 A
482 - G 1 1 1 - K1 M1 - A 1 S1 - 10 A ordering example
Preferred types
Preferred types
Standard current ratings (A)
1 3 5 6 8 10 15 20 25 30 35 40 50
482-G111-K1M1-A1S0- x x x x x x x x x x x x x
482-G212-K1M1-A1S0- x
x
xxxxxxxx
Technical data
Voltage rating
Current rating range
Auxiliary circuit
Typical life
Ambient temperature
Insulation co-ordination
(IEC 60664 and 60664A)
Dielectric strength
(IEC 60664 and 60664A)
operating area
main to aux. circuit
Insulation resistance
Interrupting capacity Icn
Interrupting capacity
(UL 1077)
Degree of protection
(IEC 60529/DIN 40050
Vibration
Shock
Corrosion
Humidity
Explosion
Mass
AC 115 V (400 Hz); DC 28 V
AC 230 (50/60 Hz) to special order
0.1...50 A
0.5 A, DC 28 V
10,000 operations mechanical
5,000 operations at IN
-55...+75 °C (-67...+167 °F)
rated impulse
withstand voltage
1.5 kV
pollution
degree
3
test voltage
AC 1,500 V
AC 1,500 V
> 100 MΩ (DC 500 V)
0.1...2.5 A
3...3.5 A
4...7 A
7.5...50 A
35...50 A
15 x IN
250 A DC / 150 A AC
500 A
6,000 A DC / 1,000 A AC
with auxiliary contact:
3,000 A DC / 1,000 A AC
IN
UN
0.1...50 A DC 72 V 5,000 A
operating area IP40
terminal area IP00
10 g (55-2000 Hz), ± 0.76 mm (10-55 Hz)
to VG 95210, sheet 19/IEC 60068-2-6, test Fc
50 g (11 ms)
to VG 95210, sheet 28/IEC 60068-2-27, test Ea
48 hours at 5 % salt mist
to VG 95210, sheet 2/IEC 60068-2-11, test Ka
240 hours at 95 % RH
to VG 95210, sheet 7/IEC 60068-2-3, test C
to VG 95210, sheet 10/MIL-STD-202,
meth. 109
approx. 43 g without auxiliary contact
approx. 46 g with auxiliary contact
Approvals
Authority
UL
CSA
Bw
Standard
UL 1077
C22.2 No 235
VG 95345,
part 21
Rated voltage
DC 72 V
DC 72 V
DC 28 V
Current ratings
0.1 A…50 A
0.1 A…50 A
0.5 A…50 A
Previous ordering codes:
482-N-MS = 482-G111-K1M1-A1S0-...A
482-MS = 482-G212-K1M1-A1S0-...A
1646
www.e-t-a.de