High Performance Thermal-Magnetic Circuit Breaker 437-...
Description
Single pole high performance thermal-magnetic circuit breaker with
tease-free, trip-free, snap action mechanism and toggle actuation
(S-type TM CBE to EN 60934). Options include auxiliary contacts, a
moulded flame retardant enclosure for added environmental protection,
and remote operation - disconnection only, or disconnection and
re-connection. Also available in an IP65 housing (see type E-1032).
Typical applications
Battery and cable protection for all types of vehicles (including rail
vehicles and boats), battery powered systems.
1
Ordering information
437-...
Type No.
437 single pole, toggle actuator
Terminal design
K12 flat screw terminals M10
K60 flat screw terminals DIN 46206, sheet 2, form 1, thread M10
Mounting
1 lugs
5 brackets
Characteristic curve
06 fast trip
07 delayed trip
Auxiliary contacts (blade terminals 6.3x08)
Si one each N/O and N/C
Si01 one N/C (11/12), two N/O (13/14 + 23/24)
Si2 one N/O (13/14)
Remote trip (optional)
FA electrical remote disconnection
FC electrical remote disconnection (FA)
and re-connection (FE)
Coil voltage
12 DC 12 V
24 DC 24 V
Current ratings
40...240 A
Voltage ratings
(blank) ≤ DC 110 V
437 - K60 - 5 - 06 - Si01-FA 24 - 50A - ... ordering example
The exact part number required can be built up from the table of choices shown
above. Ordering references for optional features should be omitted if not required.
Standard current ratings and typical internal resistance values
Current
rating (A)
40
50
63
80
100
Internal
Current
resistance (Ω) rating (A)
< 0.003
120
< 0.002
160
≤ 0.002
200
≤ 0.002
240
≤ 0.002
Internal
resistance (Ω)
≤ 0.002
≤ 0.001
≤ 0.001
≤ 0.001
Technical data
Voltage rating
DC 144 V
(higher voltage ratings upon request)
Current rating range
40...240 A
(higher current ratings upon request)
Auxiliary contact rating
6 A max. at DC 28 V
0.2 A at DC 180 V
Electrical remote disconnection (-FA)
operating voltage
DC 12 V or DC 24 V
operating current
approx. 18 A or 12 A
max. pulse time
switching time
10 ms < tON < 20 ms / tOFF > 10 s
< 20 ms
Electrical remote re-connection (-FC)
operating voltage
DC 12 V or DC 24 V
operating current
approx. 30 A or 15 A
max. pulse time
switching time
0.1 s < tON < 1.2 s / tOFF > 60 s
< 100 ms
Typical life
3,000 operations at 240 A, DC 180 V
10,000 operations at 240 A, DC 28 V
20,000 operations mechanical
Ambient temperature
-40...+60 °C (-40...+140 °F)
Insulation co-ordination rated impulse
(IEC 60664 and 60664 A) withstand voltage
6 kV
pollution
degree
3
Dielectric strength
(IEC 60664 and 60664 A)
operating area
main to aux. circuit
aux. circuits 11-12
to 13-14
test voltage
AC 3,300 V
AC 2,200 V
AC 1,000 V
Insulation resistance
> 100 MΩ (DC 500 V)
Interrupting capacity Icn
2,000 A at DC 180 V; L/R = 0 ms
10,000 A at DC 28 V; L/R = 0 ms
7,500 A at DC 28 V; L/R = 13 ms
Degree of protection
(IEC 60529/DIN 40050)
operating area IP40,
terminal area IP00
with enclusure B IP54
with enclosure C IP65
Vibration
curve 06:
curve 07:
3 g (60-500 Hz), ± 0.23 mm (10-60 Hz)
4 g (60-500 Hz), ± 0.30 mm (10-60 Hz)
to IEC 60068-2-6, test Fc,
10 frequency cycles/axis
Shock
curve 06: 20 g (11 ms), to IEC 60068-2-27, test Ea
curve 07: 25 g (11 ms), to IEC 60068-2-27, test Ea
Corrosion
48 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
Humidity
240 hours at 95 % RH,
to IEC 60068-2-3, test Ca
Mass
approx. 900 g base unit
+ approx. 400 g remote re-connection