English
Language : 

412-K14 Datasheet, PDF (1/4 Pages) –
High Performance Thermal Circuit Breaker 412-...
Description
Single pole high performance thermal circuit breaker with tease-free,
trip-free, snap action mechanism and push/pull on/off manual actuation
(M-type TO CBE to EN 60934). An indicator band on the push button
clearly shows the tripped/off position. Threadneck panel mounted and
available in tracked vehicle, aircraft and general purpose versions.
Typical applications
Extra low voltage wiring systems on all types of vehicles for land, sea
and air; defence equipment; battery powered machines.
1
Ordering information
412-...
Type No.
412 threadneck panel mounting
Terminal design
K14 screw terminals M4 (to aircraft specs.)
K54 screw terminals M4 sealed housing (to vehicle specs.)
Version
FN2 vehicle application, nickel-plated
LN2 aircraft application, black finish
N2 general application, nickel-plated
Current ratings
6...25 A (-FN2)
7.5...35 A (-LN2/N2)
412 - K14 - LN2 - 10 A ordering example
Preferred types
Preferred types
412-K54-FN2-
412-K14-LN2-
412-K54-LN2-
Standard current ratings (A)
6 7.5 8 10 15 20 25 30 35
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
Standard current ratings and typical voltage drop values
Current Voltage
rating (A) drop (mV)
-LN/N -FN
6
-
≤ 300
7.5
≤ 300 ≤ 250
8
≤ 250 ≤ 200
10
≤ 200 ≤ 200
12
≤ 200 ≤ 200
13
≤ 200 ≤ 200
Current Voltage
rating (A) drop (mV)
-LN/N -FN
15
≤ 200
≤ 200
20
≤ 200
≤ 200
25
≤ 200
≤ 200
30
≤ 200
-
35
≤ 200
-
Technical data
Voltage rating
Current rating range
Typical life
Ambient temperature
Insulation co-ordination
(IEC 60664 and 60664A)
Dielectric strength
(IEC 60664 and 60664A)
operating area
Insulation resistance
Interrupting capacity Icn
Interrupting capacity
(UL 1077)
Degree of protection
(IEC 60529/DIN 40050)
Vibration
Shock
Corrosion
Humidity
Mass
DC 28 V
AC 115 V (400 Hz) upon request
6...25 A (-FN2)
7.5...35 A (-LN2/-N2),
lower current ratings to special order
4,000 operations at 2 x IN
-55...+75 °C (-67...+167 °F)
rated impulse
withstand voltage
1.5 kV
pollution
degree
3
test voltage
AC 1,500 V
> 100 MΩ (DC 500 V)
6,000 A
6,000 A
operating area IP40
terminal area IP00
10 g (56-500 Hz), ± 0.76 mm (10-55 Hz)
to VG 95210, sheet 19,
MIL-STD-202, meth. 204,
IEC 60068-2-6, test Fc
25 g (11 ms)
to VG 95210, sheet 28,
MIL-STD-202, meth. 213,
IEC 60068-2-27, test Ea
96 hours at 5 % salt mist,
to VG 95210, sheet 2,
MIL-STD-202, meth. 101,
IEC 60068-2-11, test Ka
240 hours at 95 % RH
to VG 95210, sheet 7,
MIL-STD-202, meth. 106,
IEC 60068-2-3, test Ca
approx. 40 g
Approvals
Authority
UL
CSA
Standard
UL 1077
C22.2 No
235
Rated voltage
DC 28 V
DC 28 V
Current ratings
0.1 A...35 A
0.1 A…35 A
1646
www.e-t-a.de
1