English
Language : 

3131-A Datasheet, PDF (1/6 Pages) ETAL Group – Motor protection, transformer protection, household appliances and office equipment, electrical tools, mobile homes, watercraft, construction vehicles, medical equipment
Thermal Circuit Breaker / Switch Series 3131
Description
Combination of single pole circuit breaker and ON/OFF switch with
soft-touch rocker actuation. Contoured rockers are available with a
choice of colours and legends, with optional illumination. The 3131 is
sealed to provide IP66 rated front of panel water splash protection.
It meets the requirements of circuit breaker standard EN 60934 (IEC
60934): S type, TO.
Typical applications
Motor protection, transformer protection, household appliances and office
equipment, electrical tools, mobile homes, watercraft, construction
1
vehicles, medical equipment.
3131
Circuit breaker
Current ratings and typical internal resistance values
Current
rating (A)
0.1
0.2
0.3
0.4
0.5
0.8
1
1.2
1.5
2
2.5
3
3.5
Internal
Current
resistance (Ω) rating (A)
94
4
24
5
12
6
5.30
7
4.20
8
1.50
10
0.9
12
0.80
14
0.45
15
0.27
16
0.0785
18
0.0595
20
0.0565
Internal
resistance (Ω)
0.0435
0.0325
0.0215
0.0165
0.0165
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
Illumination voltage / power consumption
operating voltage
12 V
24 V
115 V
230 V
power consumption (LED)
Y = yellow
T = blue
10 mA
10 mA
< 1 mA
< 1 mA
10 mA
10 mA
-
-
Technical data
For further details please see chapter: Technical Information
Voltage rating
AC 240 V; DC 28 V
Current rating range
0.1...20 A
Typical life
Ambient temperature
0.1...20 A
30,000 operations at 1 x IN, inductive
-20...+60 °C (-4...+140 °F)
Insulation co-ordination 2.5 kV/2
(IEC 60664)
re-inforced insulation in the operating area
Dielectric strength
operating area
test voltage AC 3,000 V
current path/current path test voltage AC 1,500 V
Insulation resistance
> 100 MΩ (DC 500 V)
Interrupting capacity Icn 0.1...2 A 10 x IN
2.5...20 A 200 A
Interrupting capacity
(UL 1077)
0.1...16 A:
AC 240 V
DC 32 V
3,000 A
2,500 A
Protection class
(IEC 60529)
operating area IP66
terminal area IP00
Vibration
5 g (57-500 Hz) ± 0.38 mm (10-57 Hz)
test to IEC 60068-2-6, test Fc,
10 frequency cycles/axis
Shock
25 g (11 ms),
test to IEC 60068-2-27, test Ea
Corrosion
96 hours at 5 % salt mist,
test to IEC 60068-2-11,test Ka
Humidity
240 hours at 95 % RH,
test to IEC 60068-2-78, test Cab
Mass
approx. 30 g
Approvals
Authority
VDE
UL
Standard
Rated
voltage
IEC 60934
AC 240 V
DC 32 V
UL 1077
C22.2 No 235
UL 1500
Ignition Protected
AC 250 V
DC 50 V
DC 32 V
Current ratings
0.05 A…20 A
0.05 A…20 A
0.1 A…20 A
2 A…20 A
0.1 A…20 A
1646
www.e-t-a.de
1