Thermal Circuit Breaker 3120-F...
Description
The 3120 circuit breaker/switch combination is an ON/OFF switch
with integral overcurrent protection (S-type TO CBE to EN/IEC
60934). The trip element is a bimetal. Type 3120 is ideally suited for
overload protection of motors, pumps, transformers and cables.
Product characteristics:
l rocker or push button actuation
l single pole and double pole versions
l reliable switching behaviour (positively trip-free)
l convenient snap-in mounting
l international approvals
1
Options and add-on modules:
l illumination
l water splash protection
l auxiliary contacts
l under voltage trip
l remote trip
Technical data
l magnetic trip (see thermal-magnetic circuit breakers)
l push-in terminals
For details please see Technical information
l appliance inlet module
Rated voltage
AC 240 V, DC 50 V
Typical applications
Current rating range
0.1...20 A
(up to 30A upon request for single pole
units)
Medical and laboratory equipment, apparatus and machine
construction, professional tools, household and garden appliances,
offices machines, audio equipment, machine tools
Current ratings and internal resistance values
Current rating Internal
(A)
resistance
per pole (Ω)
0.1
94
0.2
24
Current rating Internal
(A)
resistance
per pole (Ω)
4
0.0435
4.5
0.0435
Typical life 1-pole
AC 240 V:
DC 50 V:
DC 28 V:
0.1...20 A
0.1...4 A
4.5...16 A
0.1...20 A
Typical life 2-pole
30,000 operations at 1 x IN, inductive
30,000 operations at 1 x IN, inductive
30,000 operations at 1 x IN, resistive
30,000 operations at 1 x IN, inductive
AC 240 V:
DC 50 V:
0.1...16 A
17...20 A
0.1...16 A
17...20 A
50,000 operations at 1 x IN, inductive
30,000 operations at 1 x IN, inductive
50,000 operations at 1 x IN, inductive
50,000 operations at 1 x IN, inductive
Ambient temperature -30 … 60 °C
Insulation coordination 2.5 kV /2 reinforced insulation at
(IEC 60664)
operating area
0.3
12
5
0.0325
Dielectric strength
0.4
5.30
6
0.5
4.20
7
0.6
2.90
8
0.8
1.50
10
1
0.9
12
1.2
0.80
14
1.5
0.45
15
2
0.27
16
2.5
0.0785
18
3
0.0595
20
3.5
0.0565
0.0215
0.0165
0.0165
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
Current consumption of illumination
Operating voltage
DC 12 V
DC 24 V
DC 48 V
AC 115 V
AC 230 V
Current consumption
Y
R
5.2 mA
2 mA
4.5 mA
2.2 mA
4.5 mA
2 mA
2.8 mA
1.1 mA
2.2 mA
0.9 mA
G
1.4 mA
1.6 mA
1.6 mA
1 mA
0.9 mA
Operating area
pole to pole (2-pole)
test voltage AC 3,000 V
test voltage AC 1,500 V
Insulation resistance
> 100 MΩ (DC 500 V)
Interrupting capacity Icn 0.1...2 A
2.5...20 A
10 x IN
1-pole 150 A
2-pole 250 A
Interrupting capacity (UL 1077)
1-pole, 2- pole
IN
0.1...20 A
UN
AC 250 V
Inc
5000 A, C, 1
1-pole, 2- pole 0.1...20 A
DC 50 V
1000 A, C, 1
Degree of protection
(IEC 60529)
Vibration
Shock
Corrosion
Humidity
Mass
operating area IP40
terminal area IP00
with water splash cover IP54 or IP66
8 g (57-500 Hz), ± 0.61 mm (10-57 Hz)
test to IEC 60068-2-6, test Fc
10 frequency cycles/axis
30 g (11 ms)
test to IEC 60068-2-27, test Ea
96 hours at 5 % salt mist,
test to IEC 60068-2-11, test Ka
240 hrs in 95 % RH
test to IEC 60068-2-78,
test Cab
approx. 33 g (2-pole)
approx. 27 g (1-pole)
approx. 42 g (2-pole with PT terminals)
1616
www.e-t-a.de