English
Language : 

1657-G21 Datasheet, PDF (1/4 Pages) ETAL Group – Power tools, Industrial equipment, Medical equipment, Power generators, Motors, Battery chargers, UPS
Thermal Overcurrent Circuit Breaker 1657-...
Description
Single pole thermal reset circuit breaker in a miniaturised design
intended for thread neck mounting. Easy and quick reset after
tripping due to overcurrent. Trip-free mechanism and automatic
disconnection in the event of an overcurrent, even with a blocked
actuator button. R-Type TO CBE to EN60934. Very cost effective
design to meet international requirements.
l Manual reset, trip free mechanism
l Extremely small and lightweight
Typical applications
1
Power tools, Industrial equipment, Medical equipment, Power generators,
Motors, Battery chargers, UPS.
1657-...
Ordering information
Type No.
1657 single pole thermal circuit breaker, black body
Threadneck design
G11 M11x1,0 (Plastic), white push-to-reset button
G12 M11x1,0 (Plastic), black push-to-reset button
G21 3/8“-24 UNF (Plastic), white push-to-reset button
G22 3/8“-24 UNF (Plastic), black push-to-reset button
Hardware
00 no hardware
01 one integrated knurled nut (plastic),
Y 310 777 01 for M11, Y 310 778 01 for 3/8", bulk
Terminals
P10 blade terminals A6.3-0,8 (QC .250)
P13 blade terminals A6.3-0,8 (QC .250), 90°
S83 bent screw terminals 8-32 UNC
Current ratings
5/6/7/8/10/12/15/20 A
1657-G21 -01 - P10 -5 A Ordering example
Standard current ratings and typical resistance
Current
rating (A)
5A
6A
7A
8A
Typical
Current
Resistance (Ω) rating (A)
0.225
10 A
0.175
12 A
0.175
15 A
0.175
20 A
Typical
Resistance (Ω)
0.125
0.125
0.050
0.040
Approvals
Authority
UL
TÜV SÜD
UL
Standard
UL 1077
(E67320)
EN 60934 /
IEC 60934
UL 1500
Voltage rating
AC 250 V
DC 50 V
AC 250 V
DC 32 V
AC 250 V
DC 50 V
Current ratings
5 A...20 A
5 A...20 A
5 A...12 A
5 A...20 A
5 A...20 A
5 A...20 A
Technical data
Voltage rating
AC 250 V, DC 32 V
Current ratings
5...12 A inductive load
13...20 A resistive load
Typical life
Behaviour at rated
switching capacity
(EN 60934;
test sequence D)
500 operations at 1.5 x In resistive
AC 125 V
operat. IN
UN
40
5...12 A AC 250 V 6 x In ind.
40
5...20 A DC 32 V 4 x In ind.
Ambient temperatur
-10 °C to +60 °C (+14...+140° F)
Insulation co-ordination 2,5 kV/2 reinforced insulation in
(IEC 60664)
operating area
Dielectric strength
operating area
test voltage AC 3,000 V
Insulation resistance
> 500 MΩ
Interrupting capacity (Icn) IN
UN
5...12 A AC 250 V 6 x In
5...20 A DC 32 V 6 x In
Interrupting capacity
(UL 1077)
IN
UN
INC
5...20 A AC 250 V 1000 A, C, 1
5...20 A AC 250 V 400 A, U, 3
5...20 A DC 50 V 300 A, C, 1
Degree of protection
(IEC 60529)
operating area IP40
terminal area IP00
Vibration
57 Hz acceleration 30m/s2 (3 g)
in X.Y.Z. direction (2 timesl/min.)
Shock
300m/s2 (30 g) in X.Y.Z. direction
Mass
approx. 14 g
050215
www.e-t-a.de
1