English
Language : 

1160-02-12A Datasheet, PDF (1/2 Pages) ETAL Group – Automotive and marine extra low voltage wiring systems and components, battery powered appliances
Thermal Automotive Circuit Breaker 1160-...
Description
Thermal circuit breaker, with controlled self-resetting mechanism,
specially suited to installation in inaccessible locations. Under overload
conditions the circuit breaker contacts will open to protect the load
circuit. A low current excitation circuit ensures that the contacts remain
open thereby avoiding the hazards of automatic reset operation. The
circuit breaker is reset by switching off the supply circuit for a short
period. Class 2 device, contacts stay open until voltage is removed.
Type II to SAE J 553.
Typical applications
1
Automotive and marine extra low voltage wiring systems and components,
battery powered appliances.
1160-...
Ordering information
Type No.
1160 single pole plug-in type
Design standard
02 standard version 12 V
Current ratings
12, 15, 20, 30 A
1160 - 02 - 12A ordering example
Standard current ratings and typical voltage drop values
Current rating (A)
12
15
20
30
Voltage drop (mV)
< 150
< 150
< 150
< 150
Technical data
Voltage rating
Current ratings
Typical life
Ambient temperature
Holding current
Reset time at 23°C after
5 s of load with UN
Interrupting capacity
(o-o-o)
Degree of protection
(IEC 60529/DIN 40050)
Vibration
Shock
Corrosion
Humidity
Mass
DC 12 V
12...30 A
300 operations at 2 x IN
-30...+60 °C (-22...+140 °F)
< 0.6 A
< 35 sec
200 A, L/R = 2.5 ms
housing area IP54
terminal area IP00
5 g (57-500 Hz) ± 0.38 mm (10-57 Hz),
to IEC 60068-2-6, test Fc,
10 frequency cycles/axis
25 g (11 ms)
to IEC 60068-2-27, test Ea
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
240 hours at 95 % RH
to IEC 60068-2-78, test Cab
approx. 6 g
1646
www.e-t-a.de
1