English
Language : 

PKG4428PI Datasheet, PDF (5/20 Pages) Ericsson – DC/DC converter Input 36-72 Vdc Output up to 15A/60W
PKG 4319 PI
TC = –30…+90°C, VI = 36 ...72V unless otherwise specified.
Output
Characteristics
Output voltage initial
setting and accuracy
VOi
Output adjust range1)
Conditions
TC = +25°C, IO = 15 A, VI = 53 V
Output 1
min
typ
max
2.49
2.51
2.53
2.25
2.75
Output voltage
VO
tolerance band
Idling voltage
Line regulation
Load regulation
ttr
Load transient
recovery time
Vtr
Load transient voltage
Tcoeff
tr
Temperature coefficient2)
Ramp-up time
ts
Start-up time
IO
PO max
Ilim
Isc
VO ac
SVR
OVP
Output current
Max output power3)
Current limiting
threshold
Short circuit current
Output ripple
Supply voltage
rejection (ac)
Over voltage protection
Long term drift
included
IO=0.1 …1.0 × IOmax
IO = 0 A
IO =IOmax
VI = 36…60 V
VI = 50…72 V
IO=0.1 …1.0 × IOmax, VI = 53 V
IO=0.1 … 1.0 × IOmax, VI = 53 V
load step = 0.5× IOmax
IO =IO max, TC <TC max
IO=
0.1…1.0 × IOmax
VI = 53 V
0.1 …0.9 × VO
From VI connection
to VO = 0.9 × VOi
Calculated value
TC < TC max
VO =0.2 … 0.5 V, TA =25°C, RSC >25 mΩ
IO =IO max
20 Hz…5 MHz
f = 100 Hz sine wave, 1 Vp-p, VI = 53 V
(SVR = 20 log (1 Vp-p/VOp-p))
IO > 0.1 × IO max
2.43
2.57
4.0
5
5
30
100
+250
– 500
see PKG 4319 PI Temperature characteristics
30
60
0
15
38
15.3
22
60
100
47
4.2
1)See Operating information.
2)Temperature coefficient is positive at low temperatures and negative at high temperatures.
3)See also Typical Characteristics, Power derating.
Unit
V
V
V
V
mV
mV
µs
mV
mV
ms
ms
A
W
A
A
mVp-p
dB
V
Miscellaneous
Characteristics
η
Efficiency
Pd
Power dissipation
Conditions
IO= IOmax, VI = 53 V
IO= IOmax, VI = 53 V
PKG 4000 I Series DatasheetEN/LZT 146 04 R3A© Ericsson Power Modules, April 2007
min
typ
max
Unit
78
%
10.7
W