English
Language : 

PKG2000 Datasheet, PDF (5/16 Pages) Ericsson – 46-60 W DC/DC Power Modules 24 V Input Series
PKG 2410 PI
TC = – 30 …+ 90°C, VI = 19…36 V unless otherwise specified.
Output
Characteristics
Output voltage initial
setting and accuracy
VOi
Output adjust range1)
Conditions
TC = +25 °C, IO = IOmax, VI = 26 V
min
3.28
2.40
Output 1
typ
3.30
max
3.32
3.65
Output voltage
VO
tolerance band
Idling voltage
Long term drift
included
IO = 0 A
IO = 0.1 …1.0 ´ IO max
Line regulation
IO = IO max
Load regulation
IO= 0.1 …1.0 ´ IOmax, VI = 26 V
ttr
Load transient recovery time
Vtr
Load transient voltage
IO=0.1 … 1.0 ´ IOmax, VI = 26 V
load step = 0.5× IOmax
Tcoeff
tr
Temperature coefficient2)
Ramp-up time
ts
Start-up time
IO
PO max
Ilim
Output current
Max output power3)
Current limiting
threshold
IO =IO max, TC <TC max
IO=
0.1…1.0 ´ IO max
0.1 …0.9 ´ VO
From VI connection
to VO = 0.9 ´ VOi
Calculated value
TC < TC max
3.10
3.40
4.0
10
35
100
150
+200
–300
see PKG 2410 Temperature characteristics
10
15
15
0
14
46
14.4
Isc
VO ac
Short circuit current
Output ripple & noise
VO =0.2 … 0.5 V, TA = 25°C
IO = IO max
20 Hz …5 MHz
0.60…30 MHz
18
60
100
70
SVR
Supply voltage
rejection (ac)
f = 100 Hz sine wave, 1 Vp-p, VI = 26 V
(SVR = 20 log (1 Vp-p/VOp-p))
45
OVP
Over voltage protection
IO > 0.1 × IO max
4
1) See Operating information.
2) Temperature coefficient is positive at low temperatures and negative at high temperatures.
3) See also Typical Characteristics, Power derating.
Unit
V
V
V
V
mV
mV
ms
mV
mV
ms
ms
A
W
A
A
mVp-p
dBmV
dB
V
Miscellaneous
Characteristics
Conditions
min
h
Efficiency
Pd
Power dissipation
IO = IOmax, VI = 26 V
IO = IO max, VI = 26 V
EN/LZT 146 03 R1A (Replaces EN/LZT 137 R5) © Ericsson Microelectronics AB, April 2000
typ
79.5
12
max
Unit
%
W
5