English
Language : 

PMB8818TP Datasheet, PDF (22/32 Pages) Ericsson – DC/DC regulator Input 8.3 - 16 V Output 16 A
Adjusted to 3.3 Vout - Typical Characteristics
General conditions: Input filter 4 x 4.7 µF, Output filter 2 x 150 µF
Efficiency
<>



7
7

7
7






 <">
Efficiency vs. load current and input voltage at Tref = +25 °C
Output Current Derating at 12 V input
<">



NT MGN 

NT MGN
NT MGN
NT MGN

NT MGN
/BU$POW

       <«$>
Available load current vs. ambient air temperature and
airflow at Vin = 12 V. See conditions on page 30.
Power Dissipation
<8>


7
7

7
7








 <">
Dissipated power vs. load current and input voltage at
Tref = +25 °C
Output Characteristic
<7>
 
 
 
7
7
 
7
7
 




Output voltage vs. load current.
 <">
Start-Up
Turn Off
Start-up at IO = 16 A resistive load at Tref= +25 °C,
Vin = 12 V. Start enabled by connecting Vin.
Top trace: output voltage (1 V/div.).
Bottom trace: input voltage (10 V/div.).
Time scale: 2 ms/div.
PMB 8818T P Datasheet
Turn-off at IO = 16 A resistive load at Tref = +25 °C,
Vin = 12 V. Turn-off enabled by disconnecting Vin.
Top trace: output voltage (1 V/div.).
Bottom trace: input voltage (10 V/div.).
Time scale: 2 ms/div.
22