English
Language : 

PKB4000 Datasheet, PDF (20/46 Pages) Ericsson – DC/DC converters, Input 36-75 V, Output 30 A/90 W
E
Ericsson Internal
PRODUCT SPECIFICATION
Prepared (also subject responsible if other)
No.
ECHWANG
2/1301-BMR 636T0e1c/1h4nUiceanl Specification
Approved
SPEKCB/D4(0B0e0ttysWeruie) s
Checked
ESECZHW
Date
2009-2-9
Rev
Reference
ECN/LZT 146 394 R5D October 2013
DC/DC converters, Input 36-75 V, Output 30 A/90 W
© Ericsson AB
2 (5)
20
3.3 V/20 A Electrical Specification
PKB 4610 PINB
Tref = -40 to +90ºC, VI = 36 to 75 V, sense pins connected to output pins unless otherwise specified under Conditions.
Typical values given at: Tref = +25°C, VI= 53 VI max IO, unless otherwise specified under Conditions.
Additional Cin = 0 μF and Cout = 0 μF. See Operating Information section for selection of capacitor types.
Characteristics
Conditions
min
typ
max
Unit
VI
Input voltage range
36
75
V
VIoff
Turn-off input voltage
Decreasing input voltage
30
30.8
32
V
VIon
Turn-on input voltage
Increasing input voltage
33
34.0
35
V
CI
Internal input capacitance
2.65
μF
PO
Output power
Output voltage initial setting
0
66
W
50 % of max IO
91.3
η
Efficiency
max IO
50 % of max IO, VI = 48 V
90.5
%
91.6
max IO, VI = 48 V
90.5
Pd
Power Dissipation
max IO
6.9
9.2
W
Pli
Input idling power
IO = 0 A, VI = 53 V
1.6
W
PRC
Input standby power
VI = 53 V (turned off with RC)
0.13
W
fs
Switching frequency
0-100 % of max IO
164
kHz
VOi
Output voltage initial setting and
accuracy
Tref = +25°C, VI = 53 V, IO = 25 A
Output adjust range
See operating information
Output voltage tolerance band 10-100 % of max IO
VO
Idling voltage
IO = 0 A
Line regulation
max IO
Load regulation
VI = 53 V, 0-100 % of max IO
Vtr
Load transient
voltage deviation
VI = 53 V, Load step 25-75-25 % of
ttr
Load transient recovery time
max IO, di/dt = 1 A/μs
tr
ts
Ramp-up time
(from 10−90 % of VOi)
Start-up time
(from VI connection to 90 % of VOi)
10-100 % of max IO
tf
VI shut-down fall time
(from VI off to 10 % of VO)
max IO
IO = 0 A
RC start-up time
max IO
tRC
RC shut-down fall time
(from RC off to 10 % of VO)
max IO
IO = 0 A
IO
Output current
Ilim
Current limit threshold
Tref < max Tref
Isc
Short circuit current
VOac Output ripple & noise
OVP Over voltage protection
Note 1: See Operating Information section.
Tref = 25ºC, see Note 1
See ripple & noise section,
max IO, VOi
Tref = +25°C, VI = 53 V, 0-100 % of
max IO
3.23
2.64
3.20
3.20
2
7
0
22
3.7
3.30
0.2
0.4
±320
32
8
12
0.08
5.2
12
0.06
5.4
25
29
43
4.1
3.37
3.63
3.40
3.40
10
10
±500
50
30
60
20
31
33
80
4.7
V
V
V
V
mV
mV
mV
μs
ms
ms
ms
s
ms
ms
s
A
A
A
mVp-p
V