English
Language : 

PBM3960-1 Datasheet, PDF (2/10 Pages) Ericsson – Microstepping Controller/Dual Digital-to-Analog Converter
PBM 3960/1
Maximum Ratings
Parameter
Voltage
Supply
Logic inputs
Reference input
Current
Logic inputs
Temperature
Storage temperature
Operating ambient temperature
* refers to DIP package
Pin no. *
5
6- 17
1
6- 17
Recommended Operating Conditions
Parameter
Supply voltage
Reference voltage
Symbol
Min
VDD
VI
-0.3
VR
-0.3
I
-0.4
I
TS
-55
TJ
-20
Max
Unit
6
V
VDD+ 0.3 V
VDD+ 0.3 V
+0.4
mA
+150
°C
+85
°C
Symbol
Min
Typ
VDD
4.75
5.0
VR
0
2.5
Max
Unit
5.25
V
3.0
V
CS
A0-A1
D0-D7
WR
DA
Sign, CD
Reset
Sign, CD
2
t cs
t as
t ds
t ch
t ah
t dh
t WR
t DAC
t pwr
tres
t pres
Figure 2. Timing.
Figure 3. Timing of Reset.