English
Language : 

BMR456 Datasheet, PDF (17/49 Pages) Ericsson – 2013- 2013- Fully regulated Advanced Bus Converters Input 36-75 V, Output up to 39 A / 468 W
E
Ericsson Internal
PRODUCT SPECIFICATION
13 (29)
Prepared (also subject responsible if other)
No.
EMAOLII
2/1301-BMR 456TUeecnhnical Specification 17
Approved
Checked
Date
Rev
Reference
SBEMCR/D4(5J6ulisaeYroiue)s Fully regulated AdvEaZnHceIXdZHBus C2o0n1v3-e0r2te-0r6s 1E/28701-FGC 101 1823 revD February 2013
Input 36-75 V, Output up to 39 A / 468 W
© Ericsson AB
Typical Characteristics
12.0 V, 35 A / 420 W
Start-up
Shut-down
BMR 456 0004/001
Start-up enabled by connecting VI at:
TP1, TP3 = +25°C, VI = 53 V,
IO = 35 A resistive load.
Output Ripple & Noise
Top trace: output voltage (5 V/div.).
Bottom trace: input voltage (50 V/div.).
Time scale: (10 ms/div.).
Shut-down enabled by disconnecting VI at:
TP1, TP3 = +25°C, VI = 53 V,
IO =35 A resistive load.
Top trace: output voltage (5 V/div.).
Bottom trace: input voltage (50 V/div.).
Time scale: (2 ms/div.).
Output Load Transient Response
Output voltage ripple at:
TP1, TP3 = +25°C, VI = 53 V,
IO = 35 A resistive load.
Trace: output voltage (50 mV/div.).
Time scale: (2 µs/div.).
Input Voltage Transient Response
Output voltage response to load current
step-change (8.75-26.25-8.75 A) at:
TP1, TP3 =+25°C, VI = 53 V, CO = 3.5 mF.
Top trace: output voltage (0.5 V/div.).
Bottom trace: output current (20 A/div.).
Time scale: (0.5 ms/div.).
Output voltage response to input voltage
Top trace: output voltage (2 V/div.).
transient at: TP1, TP3 = +25°C, VI = 36-75 V,
IO = 17 A resistive load, CO = 3.5 mF
Bottom trace: input voltage (20 V/div.).
Time scale: (0.5 ms/div.).