„ RECOMMENDED OPERATING CONDITION
Parameter
VCC to GND
Digital Input Voltage to GND
Digital Output Voltage to GND
Condition
Calibration temperature range
Operating Temperature Range
Performance parameters
are applicable
Min
3.15
GND
−0.3
−20
−40
Typ
3.3
„ OUTLINE DIMENSIONS
Max
Unit
3.45 V
VCC V
VCC V
+0.3
70
°C
85
°C
Dimension in Millimeter
NOTICE:
No part of this material may be reproduced or duplicated in any form or by any means without the written permission of Seiko Epson.
Seiko Epson reserves the right to make changes to this material without notice. Seiko Epson does not assume any liability of any kind
arising out of any inaccuracies contained in this material or due to its application or use in any product or circuit and, further, there is no
representation that this material is applicable to products requiring high level reliability, such as, medical products. Moreover, no license
to any intellectual property rights is granted by implication or otherwise, and there is no representation or warranty that anything made in
accordance with this material will be free from any patent or copyright infringement of a third party. This material or portions thereof may
contain technology or the subject relating to strategic products under the control of the Foreign Exchange and Foreign Trade Law of Japan
and may require an export license from the Ministry of Economy, Trade and Industry or other approval from another government agency.
All brands or product names mentioned herein are trademarks and/or registered trademarks of their respective companies.
©Seiko Epson Corporation 2013, All rights reserved
Sensing System Operations Division
421-8 Hino, Hino-shi, Tokyo 191-8501, JAPAN
Phone: +81-42-587-8291 FAX: +81-42-587-5117
Document code: 412572600
First issue August, 2013 in Japan
Rev.20130717
3