English
Language : 

B84112G0000B030 Datasheet, PDF (5/13 Pages) EPCOS – 2−line filters SIFI−G for enhanced insertion loss
2−line filters
SIFI−G for enhanced insertion loss
B84112G0000*
Characteristics and ordering codes of B84112G0000B* and B84112G0000G*
IR CR
LR
Ileak Case Approx. Ordering code
style weight
Approvals
A
mH mA
3 2 x 0,22 µF (X2) 2 x 10 < 0,5
2 x 4700 pF (Y2)
6 2 x 0,47 µF (X2) 2 x 3,3 < 0,5
2 x 4700 pF (Y2)
10 2 x 0,68 µF (X2) 2 x 1,8 < 0,5
2 x 4700 pF (Y2)
16 2 x 0,47 µF (X2) 2 x 1,8 < 0,5
2 x 4700 pF (Y2)
20 2 x 1,0 µF (X2) 2 x 1,8 < 0,5
2 x 4700 pF (Y2)
25 2 x 1,0 µF (X2) 2 x 1,6 < 0,5
2 x 4700 pF (Y2)
36 2 x 1,5 µF (X2) 2 x 0,8 < 0,5
2 x 4700 pF (Y2)
g
1 200
1 200
1 200
1 210
2 440
2 440
2 470
B84112G0000B030 X X X
B84112G0000B060 X X X
B84112G0000B110 X X X
B84112G0000B116 X X X
B84112G0000G120 X X X
B84112G0000G125 X X X
B84112G0000G136 X X X
Characteristics and ordering codes of B84112G0000M*
IR CR
LR
Ileak Case Approx. Ordering code
style weight
Approvals
A
3 2 x 0,22 µF (X2)
6 2 x 0,47 µF (X2)
10 2 x 0,68 µF (X2)
16 2 x 0,47 µF (X2)
20 2 x 1,0 µF (X2)
25 2 x 1,0 µF (X2)
36 2 x 1,5 µF (X2)
mH µA
2 x 10 < 2
2 x 3,3 < 2
2 x 1,8 < 2
2 x 1,8 < 2
2 x 1,8 < 2
2 x 1,6 < 2
2 x 0,8 < 2
X = approval granted
g
1 200
1 200
1 200
1 210
2 440
2 440
2 470
B84112G0000M030 X X X
B84112G0000M060 X X X
B84112G0000M110 X X X
B84112G0000M116 X X X
B84112G0000M120 X X X
B84112G0000M125 X X X
B84112G0000M136 X X X
Please read and Cautions and warnings and
Important notes at the end of this document.
Page 5 of 13
B84112-G0000-*-09-7659