English
Language : 

B81130C1103289 Datasheet, PDF (5/6 Pages) EPCOS – EMI Suppression Capacitors (MKP)
Not for new design
Technical data
B81130
X2 / 275 VAC
Max. operating temperature Top,max
Dissipation factor tan δ (in 10-3)
at 20 °C (upper limit values)
+100 °C
at 1 kHz
CR ≤ 0.1 µF
1.0
CR > 0.1 µF
1.0
Insulation resistance Rins
or time constant τ = CR  Rins
at 20 °C, rel. humidity ≤ 65%
100 kHz
CR ≤ 0.33 µF
100 000 MΩ
5.0

CR > 0.33 µF
30 000 s
(minimum as-delivered values)
DC test voltage
2121 V, 2 s
Passive flammability category
B
to IEC 40 (CO) 752
Maximum continuous AC voltage (VAC) 310 V (50/60 Hz)
Rated AC voltage (IEC 60384-14)
275 V (50/60 Hz)
Maximum continuous DC voltage (VDC) 760 V
Operating AC voltage Vop at high
TA ≤ 100 °C Vop = VAC
(continuously)
temperature
TA ≤ 100 °C Vop = 1.25  VAC (1000 h)
Damp heat test
21 days / 40 °C / 93% relative humidity
Limit values after damp heat test
Capacitance change ∆C/C
≤ 5%
Dissipation factor change ∆ tan δ ≤ 0.5  10-3 (at 1 kHz)
Insulation resistance Rins
≤ 1.0  10-3 (at 10 kHz)
or time constant τ = CR  Rins
≥ 50% of minimum
as-delivered values
5