English
Language : 

B84132-MBS_06 Datasheet, PDF (3/6 Pages) EPCOS – EMC filters
Customer-specific filters
for base stations
Circuit diagram
LINE
1
LOAD
1’
B84132-MBS
2
2’
SSB1636-N
Technical data and measuring conditions
Rated voltage VR
Rated current IR
Test voltage Vtest
Overload capability (thermal)
Leakage current Ileak
Climatic category (IEC 60068-1)
250 V DC/AC, 50/60 Hz
and 80 V DC
Referred to 60 °C ambient temperature
1700 V DC , 2 s (line/line)
1700 V DC , 2 s (lines/case)
1.5 · IR for 3 min per hour or
2.5 · IR for 30 s per hour
At 250 V AC, 50 Hz
25/100/21 (–25 °C/+100 °C/21 days damp heat test)
Characteristics and ordering codes
VR
lR
AC/DC
V
A
250
16
25
50
80
VR (V DC)
80
150
Terminal
lleak
cross section
mm2
mA
4
17
4
17
8.35
17
25
17
70
—
Rtyp
mΩ
4.8
2.9
0.8
0.7
0.39
Approx.
weight
kg
0.8
1.0
1.2
1.8
Ordering code
upon request
upon request
upon request
upon request
3.4
upon request
Please read Cautions and warnings and
Important notes at the end of this document.
3 01/06