B84110A0000A005 Datasheet, PDF (3/7 Pages) EPCOS – EMC filters | |||
|
◁ |
2-line filters
for general-purpose applications
B84110A
Technical data and measuring conditions
Rated voltage VR
Rated current IR
Test voltage Vtest
Leakage current lleak
Climatic category (IEC 60068-1)
Weight
Approvals
250 V DC/AC, 50/60 Hz
Referred to 40 °C ambient temperature
1414 V DC, 2 s (line/line)
2700 V DC, 2 s (lines/ground)
At 230 V AC, 50 Hz
25/100/21 (â25 °C/+100 °C/21 days damp heat test)
Approx. 53 g
EN 133200, UL 1283, CSA C22.2 No.8
Characteristics and ordering codes
VR
AC/DC
IR
V
A
250
0.5
1
2
4
6
CR
LR
Ileak
Ordering code
Approvals
mH
0.25 µF (X2) 2 à 39
+
2 Ã 10
2 Ã 4700 pF (Y2)
2 Ã 5.6
2 Ã 2.7
2 Ã 1.9
mA
< 0.5
< 0.5
< 0.5
< 0.5
< 0.5
B84110A0000A005 Ã
B84110A0000A010 Ã
B84110A0000A020 Ã
B84110A0000A040 Ã
B84110A0000A060 Ã
ÃÃ
ÃÃ
ÃÃ
ÃÃ
ââ
à = approval granted
Dimensional drawing
Pin layout
47,5
30
1
1â
2
2â
SSB0563-9
Please read Cautions and warnings and
Important notes at the end of this document.
3 01/06
|
▷ |