English
Language : 

B82131 Datasheet, PDF (3/7 Pages) EPCOS – Chokes and inductors
VHF chokes
Carbonyl iron core
General technical data
Test voltage Vtest
Rated inductance LR
Inductance tolerance
Rated current IR
Inductance decrease ΔL/L0
DC resistance Rtyp
Resonance frequency fres, min
Climatic category (IEC 60068-1)
Current derating Iop/IR
versus ambient temperature TA
(rated temperature TR = 60 °C)
Mounting information
B82131 ... B82134
2500 VAC, 1 min
Measuring frequency:L ≤ 10 μH
= 1 MHz
10 μH < L ≤ 1000 μH = 100 kHz
±20%
Referred to 60 °C ambient temperature,
for derating see below
≤10% (referred to initial value)
at DC load IR at 20 °C
Typical value, measured at 20 °C ambient temperature
Typical value, measured with Scalar Network Analyzer
ZAS from Rohde & Schwarz
55/125/56 (–55 °C/+125 °C/56 days damp heat test)
1.2
I op
IR 1.0
SSB0087-Q-E
0.8
0.6
0.4
0.2
00 20 40 60 80 100 ˚C 140
TA
When bending the leads, take care that the bending
point is at least 3 mm apart from the face ends of the
core and that the start-of-winding-areas are not subject-
ed to any mechanical stress.
Please read the Important notes at the end of
this document.