Reliability data
Test
Electrical endurance,
cycling
Standard
Electrical endurance,
constant
Damp heat
IEC 60738-1
IEC 60738-1
Rapid change
of temperature
Vibration
IEC 60738-1
IEC 60738-1
Climatic sequence
IEC 60738-1
Test conditions
Room temperature, Vlink,max
applied energy < Cth  (Tref  TA)
Number of cycles: 100 000
∆R25/R25
< 25%
Storage at Vmax /Top,max (Vmax)
Test duration: 1000 h
< 25%
Temperature of air: 40 °C
Relative humidity of air: 93%
< 10%
Duration: 56 days
Test according to IEC 60068-2-78
T1 = Top,min (0 V), T2 = Top,max (0 V)
Number of cycles: 5
< 10%
Test duration: 30 min
Test according to IEC 60068-2-14, Test Na
Frequency range: 10 to 55 Hz
< 5%
Displacement amplitude: 0.75 mm
Test duration: 3 × 2 h
Test according to IEC 60068-2-6, Test Fc
Dry heat: T = Top,max (0 V)
Test duration: 16 h
< 10%
Damp heat first cycle
Cold: T = Top,min (0 V)
Test duration: 2 h
Damp heat 5 cycles
Tests performed according to
IEC 60068-2-30
Please read Cautions and warnings and
Important notes at the end of this document.
Page 3 of 10