B84320Z0010H035 Datasheet, PDF (2/4 Pages) EPCOS – EMP Protection Units
EMP protection units
Analog communication and control lines
B84320Z0010H033
B84320Z0010H035
General
The EMP protection unit is sequenced, i.e. to use simultaneously the benefits of inert-gas-filled
surge arresters (extremely high surge capability) and of varistors (fast response). They are isola-
ted by a series inductor.
The arrester is housed in a plug-in socket, so it can be removed and tested without detaching the
lines.
Note on voltage figures:
The maximum voltage on the filter output depends primarily on the rise time until the arrester re-
sponds. For this reason the maximum voltage on the filter output is stated in the following table as
a function of the rising edge dv/dt of the pulse.
Technical data
Ordering code
Rated voltage VR
Rated frequency fR
Rated current IR
Number of lines
Line impedance ZL
Max. DC resistance Rmax
Permissible ambient
temperature TA
Climatic category
(EN 60068-1)
Approx. weight
Nominal DC spark-over
voltage VsdcN
Nominal surge current
(8/20 µs)
Suppression condition
B84320Z0010H033 B84320Z0010H035
60
V 140
V
0 ... 10
1
10
kHz 0 ... 10
A1
10
kHz Pass bandwidth at ZL
A TA = 40 °C
Pairs
600
Ω 600
Ω
<2
Ω <2
Ω Per line
25/+40
°C 25/+40
°C
25/085/56
300
<800
25/085/56
g 300
V <800
25 °C/+85 °C/56 days
damp heat test
g
V
5
10
I < IR
kA 5
kA 10
I < IR
kA Line/line
kA Pair/case
Maximum voltage on filter output:
At rising edge
dv/dt = 0.1 kV/µs
dv/dt = 1 kV/µs
dv/dt = 1 kV/ns1)
Unsymmetrical
≤190 V
≤260 V
≤16 V
Unsymmetrical
≤200 V
≤180 V
≤20 V
Symmetrical
≤17 V
≤15 V
≤8 V
1) Typical test pulse: rise time 10 ns, time to half value 1500 ns, charge voltage min. 50 kV, source impedance 90 Ω
2