English
Language : 

B84143-B8-R Datasheet, PDF (2/7 Pages) EPCOS – 3-Line Filters for Converters and Power Electronics
3-Line Filters
for Converters and Power Electronics
Typical circuit diagram
LINE
L1
L2
L3
B84143-B*-R
LOAD
L1’
L2’
L3’
Technical data
Rated voltage VR
Rated current I R
Test voltage VP
Overload capability
Leakage current I leak
Climatic category
SSB0805-1
440/250 V~, 50/60 Hz
Referred to 40 °C ambient temperature
1770 V–, 2 s (line/line)
2700 V–, 2 s (lines/case)
1,5 · IR for 3 min per hour or
2,5 · IR for 30 s per hour
at 230 V~, 50 Hz
25/100/21 (– 25 °C/+ 100 °C/21 days damp heat test)
in accordance with EN 60068-1
Characteristics and ordering codes
IR
Terminal
I leak
Rtyp
Approx.
cross section
weight
A
mm2
mA
mΩ
kg
8
4
< 3,5
80
3,8
12
4
< 3,5
40
3,8
16
4
< 3,5
25
3,8
25
10
< 3,5
10
5,7
36
10
< 3,5
5,0
5,7
50
10
<6
3,5
5,7
80
25
<6
2,0
16
For higher currents refer to B84143-B**-R110, page 246.
Ordering code
B84143-B8-R
B84143-B12-R
B84143-B16-R
B84143-B25-R
B84143-B36-R
B84143-B50-R
B84143-B80-R
234 03/01