English
Language : 

B84102-K Datasheet, PDF (2/5 Pages) EPCOS – Power line filters for single-phase systems Rated voltage 250 V~, 50/60 Hz Rated current 1 to 6 A
2-Line Filters
for General-Purpose Applications
B84102-K
Technical data
Rated voltage VR
Rated current IR
Test voltage VP
Leakage current l leak
Climatic category
Weight
250 V~, 50/60 Hz
Referred to 40 °C ambient temperature
1414 V–, 2 s, (line/line)
2700 V–, 2 s, (lines/ground)
at 230 V~, 50 Hz
In accordance with EN 60068-1
25/085/21 (– 25 °C/+ 85 °C/21 days damp heat test)
approx. 250 g
Characteristics and ordering codes
IR
CR
A
1
2 × 0,22 µF (X2)
+
2 × 2500 pF (Y2)
2
2 × 0,33 µF (X2)
+
2 × 2500 pF (Y2)
4
2 × 0,47 µF (X2)
+
2 × 2500 pF (Y2)
6
2 × 0,47 µF (X2)
+
2 × 0,035 µF (Y2)
LR
mH
2 × 18
2 × 10
2 × 4,7
2 × 2,2
l leak
mA
< 0,5
< 0,5
< 0,5
< 3,5
Ordering code
B84102-K30
B84102-K40
B84102-K50
B84102-K160
193 03/01