B82719C0...
General technical data
Rated voltage VR
Rated current IR
Rated inductance LR
Inductance tolerance
Inductance decrease ∆L/L0
Stray inductance LS
DC resistance Rtyp
Climatic category
Weight
42 Vac (50/60 Hz)
80 Vdc
Referred to 50 Hz and 40 °C ambient temperature
Measured with HP 4275A
at 10 kHz and 50 mV
(specified per winding)
–30/+50 %
< 10 % at dc magnetic bias with IR
Measured with HP 4275A at 100 kHz and 250 mV
Typical values, measured at 20 °C ambient temperature
40/125/56 (–40 °C/+125 °C/56 days damp heat test)
acc. to IEC 60068-1
Approx. 1,5 g
Characteristics and ordering codes
LR
LS, typ
IR
Rtyp
mH
µH
mA
Ω
4,7
0,5
500
0,4
6,8
0,5
400
0,5
10
0,6
300
1,1
22
0,8
250
1,7
33
1,5
200
2,1
47
1,7
150
2,8
VT
V–, 2 s
750
750
750
750
750
750
Ordering code
B82719C0475N365
B82719C0685N365
B82719C0106N365
B82719C0226N365
B82719C0336N365
B82719C0476N365