English
Language : 

V13-A800XN Datasheet, PDF (1/2 Pages) EPCOS – 2-Electrode-Arrester
Surge Arrester
2-Electrode-Arrester
Preliminary data
V13-A800XN
Ordering code: B88069X4380C251
DC spark-over voltage 1) 2)
Impulse spark-over voltage
at 1 kV/µs - for 99 % of measured values
- typical values of distribution
Insulation resistance at 100 Vdc
Capacitance at 1 MHz 2)
Impulse discharge current
15 operations
8/20 µs
1 operation 10/350 µs
+ 1 operation 10/350 µs
+ 1 operation 10/350 µs
+ 1 operation 10/350 µs
+ 1 operation
8/20 µs
Max. follow-on current at 255 VRMS
Weight
Operation and storage temperature
Climatic category (IEC 60068-1)
Marking, black
1) At delivery AQL 0.65 level II, DIN ISO 2859
2) In ionized mode
600 … 1000
V
< 1500
V
< 1300
V
>1
GΩ
< 2.5
pF
20
7.6
9
12
12
20
100
~ 6.5
-40 ... +90
40/ 90/ 21
800 YY O
800 - Nominal voltage
YY
- Year of production
O
- Non radioactive
kA
kA
kA
kA
kA
kA
Apeak
g
°C
AB E / AB PM
Page 1 of 2