English
Language : 

V13-A500XN Datasheet, PDF (1/2 Pages) EPCOS – 2-Electrode-Arrester
Surge Arrester
2-Electrode-Arrester
V13-A500XN
Ordering code: B88069X6940C251
DC spark-over voltage 1) 2)
Impulse spark-over voltage
at 5 kV/µs - for 99 % of measured values
(wave 1.2/50 µs; 6 kV)
Insulation resistance at 100 Vdc
Capacitance at 1 MHz 2)
Impulse discharge current
15 operations
+ 1 operation
+ 1 operation
+ 1 operation
+ 1 operation
+ 1 operation
8/20 µs
8/20 µs
8/20 µs
8/20 µs
8/20 µs
8/20 µs
1 operation 10/350 µs
+ 1 operation 10/350 µs
+ 1 operation 10/350 µs
Nominal alternating discharge current (50 Hz, 0.2 s)
Max. follow-on current at 250 VRMS; 20 times
Weight
Operation and storage temperature
Climatic category (IEC 60068-1)
Marking, black
1) At delivery AQL 0.65 level II, DIN ISO 2859
2) In ionized mode
400 ... 750
V
< 1500
V
>1
GΩ
< 2.5
pF
40
6
15
30
45
60
1.2
3
6
300
140
~ 6,5
-40 ... +90
40/ 90/ 21
500 YY O
500 - Nominal voltage
YY
- Year of production
O
- Non radioactive
kA
kA
kA
kA
kA
kA
kA
kA
kA
A
Apeak
g
°C
AB E / AB PM
Page 1 of 2
Issue 03, 26.04.2002