Switching Spark Gap
Preliminary data
CAS04XG
Ordering code: B88069X1200T502
DC spark-over voltage 1) 2)
Impulse spark-over voltage
at 100 V/µs - for 99 % of measured values
- typical values of distribution
at 1 kV/µs - for 99 % of measured values
- typical values of distribution
Insulation resistance at 300 Vdc
Capacitance at 1 MHz
Service life in customer circuit
Unit must meet
Insulation resistance
DC spark-over voltage
after 250, 500, 750 and 1000 h
Arc voltage at 1 A
Glow to arc transition current
Glow voltage
Weight
Operation and storage temperature
Climatic category (IEC 60068-1)
Marking, red
1) At delivery AQL 0.65 level II, DIN ISO 2859
2) In ionized mode
Terms in accordance with ITU-T Rec. K.12 and DIN 57845/VDE0845
350 ... 550
V
< 900
V
< 800
V
< 1200
V
< 1100
V
>1
GΩ
<1
pF
1000
h
>1
GΩ
270 ... 650
V
~ 10
V
< 100
A
~ 60
V
~ 1.5
g
-40 ... +90
°C
40/ 90/ 21
400 YYMM O
CS - Series
400 - Nominal voltage
YY
- Year of production
MM - Month of production
O
- Non radioactive
AB E / AB PM
Page 1 of 2