English
Language : 

B88069X0870T502 Datasheet, PDF (1/2 Pages) EPCOS – Switching Spark Gap
Switching Spark Gap
CAS02X-087
Ordering code: B88069X0870T502
DC spark-over voltage 1) 2)
Initial values
Ignition time tI after 150 hours in darkness 3)
at –20 °C
at +25; 125 °C
Electrical life time
Maximum increase of DC spark-over voltage
Switching operations at +25; 125 °C
Switching frequency 10 … 25 Hz
Switching frequency < 10Hz
Test circuit parameters
Open circuit voltage V0'
Loading resistance R
Discharge capacitance C
Inductance L
Discharge peak current IP
Insulation resistance at 100 Vdc
Capacitance at 1 MHz
Weight
Operation and storage temperature
Climatic category (IEC 60068-1)
Marking, red
1) At delivery AQL 0.65 level II, DIN ISO 2859
2) In ionized mode, after load
3) Time from capacitor charged to the first high voltage spark
Test circuit: Vac = 198 V; R = 36 kΩ; C = 2.2 µF
180 ... 230
V
95
≤4
≤2
99.9 100 %
≤5
≤7
s
≤3
≤4
s
25
V
2 000 000
4 000 000
Ignitions
Ignitions
230
Vac
15
kΩ
2.2
µF
10
µH
~ 300
A
> 0.1
GΩ
<2
pF
~ 1.5
g
-20 ... +125
°C
20/ 125/ 21
CS 230 YYMM O
CS - Series
230 - Nominal voltage
YY
- Year of production
MM - Month of production
O
- Non radioactive
AB E / AB PM
Page 1 of 2
Issue 04, 10.02.2004