English
Language : 

B88069X0400S102 Datasheet, PDF (1/2 Pages) EPCOS – Switching Spark Gap
Switching Spark Gap
FS04X-1JM
Ordering code: B88069X0400S102
Nominal breakdown voltage VN
400
V
Initial values
Static breakdown voltage VS 1) 2)
First ignition value VS, FTE after 24 hours in darkness
Following ignition values (selection limits)
Following ignition values VS, FIV
Breakdown voltage VB (measuring time 200 ms) 4)
First ignition value VB, FTE
Following ignition values VB, FIV
Electrical life time 3)
Breakdown voltage VB
First ignition value VB, FTE initial after 24 hours in darkness
First ignition value VB, FTE after 24 hours in darkness
Following ignition values VB, FIV
Switching operations
at - 40 °C
at - 40 °C
at +25 °C
at +25 °C
at +125 °C
Ignition time tI ≤ 60 ms 5)
Ignition time tI ≤ 200 ms
Ignition time tI ≤ 60 ms
Ignition time tI ≤ 200 ms
Ignition time tI ≤ 60 ms
Test circuit parameters
Open circuit voltage V0
Loading resistance R
Discharge capacitance C
Inductance L
Discharge peak current IP
General technical data
Insulation resistance at 100 V
Early ignition values below 340 V
Breakdown time
Maximum switching frequency
Maximum loading current
Weight
Marking, blue
1) At delivery AQL 0,65 level II, DIN ISO 2859
2) Page 2, Fig. 1 and 2
3) Page 2, Fig. 3 and 4
4) Page 2, Fig. 3 and 4, 100 % outgoing inspection
5) After storage in darkness for 30 days
≤ 460
V
360 ... 420
V
350 ... 430
V
≤ 460
V
340 ... 460
V
≤ 460
≤ 500
340 ... 460
60 000
100 000
100 000
200 000
200 000
V
V
V
Ignitions
Ignitions
Ignitions
Ignitions
Ignitions
500
V
10
kΩ
680
nF
0.5
µH
~ 500
A
> 100
MΩ
≤2
%
≤ 50
ns
200
Hz
50
mA
~2
g
400 WWY O
400 - Nominal voltage
WW - Calendar week of production
Y
- Year of production
O
- Non radioactive
AB E / AB PM
Page 1 of 2
Issue 05, 11.03.2003