English
Language : 

B59300M1060A070 Datasheet, PDF (1/5 Pages) EPCOS – Motor Protection, Triple Sensors
Sensors
Motor Protection, Triple Sensors
B59300
M 1300
Applications
I Thermal protection of winding in electric motors
I Limit temperature monitoring
Features
I Thermistor pellets with insulating encapsulation in
series connection (triple sensor)
I Low-resistance type
I Silver-plated and Teflon-insulated AWG 26 litz wires
I Characteristics for nominal threshold temperatures of
Dimensions in mm
90 up to 160 °C conform with DIN 44082
I Color coding of litz wires to DIN 44082, connecting wires in yellow
Delivery mode
I Bulk
General technical data
Max. operating voltage
(TA = 0 … 40 °C)
Vmax
Max. measuring voltage
(TA – 25 K … TNTT + 23 K) Vmeas,max
Rated resistance
(VPTC ≤ 2,5 V)
RN
Insulation test voltage
Vins
Thermal threshold time
ta
Operating temperature range (V ≤ Vmeas, max)
Top
(V = Vmax)
Top
30
7,5
≤ 300
2,5
<3
– 25/ TNTT + 23
0/+ 40
VDC
VDC
Ω
kV AC
s
°C
°C
Electrical specifications and ordering codes
TNTT ± ∆T
°C
60 ± 5
70 ± 5
80 ± 5
90 ± 5
100 ± 5
110 ± 5
120 ± 5
130 ± 5
140 ± 5
145 ± 5
150 ± 5
155 ± 5
160 ± 5
R (TNTT – ∆T) R (TNTT + ∆T) R (TNTT + 15 K) R (TNTT + 23 K) Ordering code
(VPTC ≤ 2,5 V) (VPTC ≤ 2,5 V) (VPTC ≤ 7,5 V) (VPTC ≤ 2,5 V)
Ω
Ω
Ω
Ω
≤ 1710
≥ 1710
—
≥ 30 k
B59300M1060A070
≤ 1710
≥ 1710
—
≥ 30 k
B59300M1070A070
≤ 1710
≥ 1710
—
≥ 30 k
B59300M1080A070
≤ 1650
≥ 3990
≥ 12 k
—
B59300M1090A070
≤ 1650
≥ 3990
≥ 12 k
—
B59300M1100A070
≤ 1650
≥ 3990
≥ 12 k
—
B59300M1110A070
≤ 1650
≥ 3990
≥ 12 k
—
B59300M1120A070
≤ 1650
≥ 3990
≥ 12 k
—
B59300M1130A070
≤ 1650
≥ 3990
≥ 12 k
—
B59300M1140A070
≤ 1650
≥ 3990
≥ 12 k
—
B59300M1145A070
≤ 1650
≥ 3990
≥ 12 k
—
B59300M1150A070
≤ 1650
≥ 3990
≥ 12 k
—
B59300M1155A070
≤ 1650
≥ 3990
≥ 12 k
—
B59300M1160A070
173 10/02