English
Language : 

EU1010_15 Datasheet, PDF (12/22 Pages) Eorex Corporation – 8-bit MCU with 10-bit A/D Converter
EU1010
underflow. It means that timer1 data will be loaded from T1BF0(06H) and T1BF1(07H) buffer after T1EN
bit is set as “1” or timer1 underflow.
Address 08H
bit7
bit6
bit5
bit4
bit3
bit2
bit1
bit0
Name T1C T1EN T1F T1CK PWM
#
`Timer1 pre-scaler
Read or Write
W
R/W
R/W
W
#
W
W
W
Default Value
0
#
#
0
#
#
#
#
Note:
*T1EN : timer1 enable flag
T1EN = 1, enable timer1 start to down count;
T1EN = 0, stop timer1 down count. (when T1EN=0 and write data into T1BF0(06H) and
T1BF1(07H) , the data will be directly passed to timer1 counter.)
*T1F : timer1 underflow flag
T1F = 1, timer1 underflow;
T1F = 0, timer1 not underflow.
Bit2~bit0 are timer1 clock source selection bits. It must follow the setting as below.
bit2 bit1
0
0
0
0
0
1
0
1
1
#
bit0 Timer1 pre-scaler (FCLK1= )
0
FOSC/1
1
FOSC/2
0
FOSC/4
1
FOSC/8
#
FOSC/16
PWM Mode
Nov.2010
12/22