English
Language : 

EL123APBP Datasheet, PDF (1/1 Pages) Energizer – Industry Standard Dimensions
PRODUCT DATASHEET
1-800-383-7323 US/CAN
www.energizer.com
ENERGIZER 123
(EL123AP)
Industry Standard Dimensions
mm (inches)
17.00 (0.669)
16.00 (0.630)
9.60 (0.378)
Maximum
This Battery has Underwriters
Laboratories component Recognition
1.00 (0.039)
Minimum
Specifications
Classification:
Chemical System:
Designation:
Nominal Voltage:
Storage Temp:
Operating Temp:
Typical Capacity:
Typical Weight:
Typical Volume:
Max Discharge:
Max Rev Current:
Typical Li Content:
UL Listed:
"Lithium"
Lithium / Manganese Dioxide (Li/MnO2)
ANSI-5018LC, IEC-CR17345
3.0 Volts
-40°C to 60°C (-40°F to 140°F)
-40°C to 60°C (-40°F to 140°F)
1500 mAh (to 2.0 volts)
(Rated at 100 ohms at 21°C)
16.5 grams (0.58 oz.)
7.0 cubic centimeters (0.4 cubic inch)
1500 mA continuous (3500 mA pulse)
2 uA
0.55 grams (0.019 oz.)
MH29980
33.50 (1.319)
Minimum
34.50 (1.358)
Maximum
Typical Discharge Characteristics
Rated Capacity
100 ohms continuous at 21°C
3.5
0.90 (0.035)
3.0
0.50 (0.020)
11.00 (0.433)
Minimum
2.5
This battery contains a Positive Temperature
Coefficient (PTC) safety device to limit current
2.0
during short circuit conditions.
Simulated Application Tests
Typical Use Performance
Type
(time)
Capacity
(continuous)
Photoflash
(3 / 27 sec)
Photoflash
(3 / 7 sec)
Photoflash
(3 / 7 sec)
Drain
(mA)
---
900
1200
1800
Load
(ohms)
100
Cutoff Voltage
2.0V (21°C) 1.8V (21°C) 1.55V (21°C)
(hours) (pulses) (pulses)
58
---
---
---
---
---
2000
---
---
1370
---
---
---
860
---
1.5
0
3.0
2.5
2.0
1.5
1.0
0
20
40
60
Hours
Photoflash
1200 mA (3 sec on / 7 sec off)
-20°C
300
600
21°C
900
1200 1500
Pulses
Important Notice
This datasheet contains typical information specific to products manufactured at the time of its publication.
©Energizer Holdings, Inc. - Contents herein do not constitute a warranty.
Form No. EBC - 4204K
Page 1 of 1